Show simple item record

dc.contributor.authorKabasakal, Levent
dc.contributor.authorAsa, Sertac
dc.contributor.authorKanmaz, Bedii
dc.contributor.authorSager, Sait
dc.contributor.authorOcak, Meltem
dc.contributor.authorUslu, Lebriz
dc.contributor.authorMaecke, Helmut
dc.contributor.authorSager, Gunes
dc.contributor.authorOnsel, Cetin
dc.contributor.authorHalac, Metin
dc.date.accessioned2021-03-02T22:43:13Z
dc.date.available2021-03-02T22:43:13Z
dc.date.issued2013
dc.identifier.citationSager S., Kabasakal L., Ocak M., Maecke H., Uslu L., Halac M., Asa S., Sager G., Onsel C., Kanmaz B., "Clinical value of technetium-99m-labeled octreotide scintigraphy in local recurrent or metastatic medullary thyroid cancers: A comparison of lesions with 18F-FDG-PET and MIBI images", Nuclear Medicine Communications, cilt.34, sa.12, ss.1190-1195, 2013
dc.identifier.issn0143-3636
dc.identifier.othervv_1032021
dc.identifier.otherav_0e467abb-7084-4102-8d1b-40767e0593b3
dc.identifier.urihttp://hdl.handle.net/20.500.12627/15179
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84887236202&origin=inward
dc.identifier.urihttps://doi.org/10.1097/mnm.0000000000000006
dc.description.abstractAimVarious studies have been conducted for determining the most optimal method for the early diagnosis of local recurrent or distant metastatic thyroid cancers. The aim of this study was to evaluate the clinical utility of technetium-99m (Tc-99m)-labeled octreotide derivatives in the detection of recurrence or distant metastases in medullary thyroid cancer patients and to compare the lesions with those detected using F-18-fluorodeoxyglucose (F-18-FDG)-PET and Tc-99m MIBI studies in the same patient group.Patients and methodsSixteen medullary thyroid cancer patients [two male and 14 female; mean age 52.014.1 years (range 13-72 years)] were included in this study. All patients underwent a whole-body scan 1 and 4 h after injection with octreotide derivatives and single photon emission computed tomography images were taken of the sites suspicious for metastasis. The lesions seen in Tc-99m HYNIC octreotide studies were compared with those seen in F-18-FDG-PET and Tc-99m MIBI studies.ResultsAmong the Tc-99m-labeled octreotide scintigraphy studies, nine were evaluated as true positive (56.2%) and one was evaluated as false positive (6.2%); six were false negative (37.5%). In 16 patients, the total number of lesions seen on octreotide scintigraphy was 21. Thirteen of the 16 patients underwent F-18-FDG-PET imaging. Of the 13 patients studied, 10 showed true-positive (76.9%) and three showed false-negative (23.1%) results. The total number of lesions seen on F-18-FDG-PET was 23. The Tc-99m MIBI study yielded positive results in seven of 16 patients (43.7%) and negative results in nine patients (56.3%). The total number of lesions on Tc-99m MIBI was 12.ConclusionThe Tc-99m-labeled somatostatin receptor scintigraphy analogs HYNIC-tyrosine octreotide and HYNIC-TATE are useful imaging alternatives in somatostatin receptor-expressing thyroid cancers. Radiolabeling using these analogs is easy and they are readily available for routine use. (C) 2013 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
dc.language.isoeng
dc.subjectRADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME
dc.subjectNükleer Tıp
dc.subjectDahili Tıp Bilimleri
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.titleClinical value of technetium-99m-labeled octreotide scintigraphy in local recurrent or metastatic medullary thyroid cancers: A comparison of lesions with 18F-FDG-PET and MIBI images
dc.typeMakale
dc.relation.journalNuclear Medicine Communications
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume34
dc.identifier.issue12
dc.identifier.startpage1190
dc.identifier.endpage1195
dc.contributor.firstauthorID77209


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record