Basit öğe kaydını göster

dc.contributor.authorCannata, V.
dc.contributor.authorCerutti, S.
dc.contributor.authorSEFER, Semih
dc.contributor.authorGenovese, E.
dc.contributor.authorNocchi, F.
dc.contributor.authorFranchin, T.
dc.date.accessioned2022-02-18T08:54:07Z
dc.date.available2022-02-18T08:54:07Z
dc.identifier.citationFranchin T., SEFER S., Cannata V., Genovese E., Nocchi F., Cerutti S., "A robust independent component analysis algorithm for removing ballistocardiogram artifacts from EEG and fMRI recordings", 4th European Conference of the International Federation for Medical and Biological Engineering (ECIFMBE), Antwerp, Belçika, 23 - 27 Kasım 2008, cilt.22, ss.1286-1289
dc.identifier.othervv_1032021
dc.identifier.otherav_04e4eec0-2d58-4db4-86a9-9499460d966f
dc.identifier.urihttp://hdl.handle.net/20.500.12627/176070
dc.description.abstractSimultaneous electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) recordings provide complementary advantages with regard to the temporal and spatial resolution of brain activity. This methodology still now suffers from several artifacts, such as the gradient, the ballistocardiogram (BCG) and electro-oculogram (EOG). A number of procedures have been developed in recent years for removing BCG artifacts and the usefulness of Independent Component Analysis (ICA) in this purpose was largely discussed and demonstrated. The aim of this study is to propose a more efficient and robust independent component analysis algorithm (RobustICA) for removing BCG and EOG artifacts. The algorithm has been validated on EEG datasets acquired inside the static magnetic field of a 1,5 T RM scanner and its performances were compared with those of other already applied processing methods (Optimal Basis Set, FastICA).
dc.language.isoeng
dc.subjectGeneral Engineering
dc.subjectEngineering (miscellaneous)
dc.subjectBiomedical Engineering
dc.subjectBioengineering
dc.subjectPhysical Sciences
dc.subjectBiyomedikal Mühendisliği
dc.subjectMühendislik ve Teknoloji
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, BİYOMEDİKSEL
dc.titleA robust independent component analysis algorithm for removing ballistocardiogram artifacts from EEG and fMRI recordings
dc.typeBildiri
dc.contributor.departmentChildrens Hosp Bambino Gesu , ,