Detection of Sleep-Disordered Breathing with Pressure Bed Sensor

Yazar
Kortelainen, Juha M.
Mendez, Martin O.
van Gils, Mark
Guerrero, Guillermina
Tenhunen, Mirja
Tachino, Giulia
SEFER, Semih
Palacios, Elvia
Üst veri
Tüm öğe kaydını göster
Özet
A Pressure Bed Sensor (PBS) can offer an unobtrusive method for sleep monitoring. This study focuses on the detection of the sleep related breathing disorders using a PBS in comparison to the methods used in a sleep laboratory. A newly developed PCA modeling approach for the eight sensor signals of the PBS is evaluated using the Reduced Respiratory Amplitude Index (RRAI) as a central measure. The method computes the respiration amplitude with the Hilbert transform, and then detects the events based on a 20% amplitude reduction from the baseline signal. A similar calculation was used for the sleep laboratory RIP measurements, and both PBS and RIP were compared against the reference based on the nasal flow signal. In the reference RRAI method, the respiratory-disordered events were obtained using RemLogic respiration analyzer to detect over 50% amplitude reduction in the nasal respiratory flow, but removing the RemLogic standard hypopnea event associations on the oxygen desaturation events and the sleep arousals. The movement artifacts were automatically detected based on the movement activity signal of the PBS. Twenty-five (25) out of 28 patients were finally analysed. On average 87% of a night measurement has been covered by the system. The correlation coefficient was 0.92 between the PBS and the reference RRAI, and the performance of the PBS was similar with the RIP belts. Classifying the severity of the sleep related breathing by dividing RRAI in groups according to the severity criteria, the sensitivity was 92% and the specificity was 70% for the PBS. The results suggest that PBS recording can provide an easy and un-obstructive alternative method for the detection of the sleep disordered breathing and thus has a great promise for the home monitoring.
Bağlantı
http://hdl.handle.net/20.500.12627/176580
Koleksiyonlar
  • Bildiri [64839]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV