Show simple item record

dc.contributor.authorAssecondi, S.
dc.contributor.authorHallez, H.
dc.contributor.authorVan Hese, P.
dc.contributor.authorD'Asseler, Y.
dc.contributor.authorLemahieu, I.
dc.contributor.authorBianchi, A. M.
dc.contributor.authorBoon, P.
dc.date.accessioned2022-02-18T09:30:23Z
dc.date.available2022-02-18T09:30:23Z
dc.identifier.citationAssecondi S., Van Hese P., Hallez H., D'Asseler Y., Lemahieu I., Bianchi A. M. , Boon P., "Ballistocardiographic artifact removal from simultaneous EEG/FMRI recording by means of canonical correlation analysis", 1st International Conference on Bio-Inspired Systems and Signal Processing, Funchal, Portekiz, 28 - 31 Ocak 2008, ss.11-16
dc.identifier.othervv_1032021
dc.identifier.otherav_425ef956-85ff-4c1e-acb1-b9251175ba85
dc.identifier.urihttp://hdl.handle.net/20.500.12627/177363
dc.description.abstractThe electroencephalogram (EEG) is a standard technique to record and study the brain activity with a high temporal resolution. Blood oxygenation level dependent functional magnetic resonance imaging (BOLD fMRI) is a non-invasive imaging method that allows the localization of activated brain regions with a high spatial resolution. The co-recording of these two complementary modalities can give new insights into how the brain functions. However, the interaction between the strong electromagnetic field (3T) of the MR scanner and the currents recorded by the electrodes placed on the scalp generates artifacts that obscure the EEG and diminish its readability.
dc.language.isoeng
dc.subjectRadiology, Nuclear Medicine and Imaging
dc.subjectRadiological and Ultrasound Technology
dc.subjectPhysical Sciences
dc.subjectHealth Sciences
dc.subjectEngineering (miscellaneous)
dc.subjectMÜHENDİSLİK, BİYOMEDİKSEL
dc.subjectMühendislik
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectGÖRÜNTÜLEME BİLİMİ VE FOTOĞRAF TEKNOLOJİSİ
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (MED)
dc.subjectTıp
dc.subjectRADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME
dc.subjectSağlık Bilimleri
dc.subjectDahili Tıp Bilimleri
dc.subjectNükleer Tıp
dc.subjectBiyomedikal Mühendisliği
dc.subjectMühendislik ve Teknoloji
dc.subjectGeneral Engineering
dc.subjectBiomedical Engineering
dc.subjectBioengineering
dc.titleBallistocardiographic artifact removal from simultaneous EEG/FMRI recording by means of canonical correlation analysis
dc.typeBildiri
dc.contributor.departmentGhent University , ,
dc.contributor.firstauthorID3375231


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record