• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   Home
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • View Item
  •   Home
  • Avesis
  • Dokümanı Olmayanlar
  • Makale
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Direct Determination of Peroxide Explosives on Polycarbazole/Gold Nanoparticle-Modified Glassy Carbon Sensor Electrodes Imprinted for Molecular Recognition of TATP and HMTD

Date
2022
Author
SAĞLAM, ŞENER
APAK, MUSTAFA REŞAT
ARDA, AYŞEM
Metadata
Show full item record
Abstract
© 2022 American Chemical Society. All rights reserved.Since peroxide-based explosives (PBEs) lack reactive functional groups, they cannot be determined directly by most detection methods and are often detected indirectly by converting them to H2O2. However, H2O2 may originate from many sources, causing false positives in PBE detection. Here, we developed a novel electrochemical sensor for the direct sensitive and selective determination of PBEs such as triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD) using electrochemical modification of the glassy carbon (GC) electrode with PBE-memory polycarbazole (PCz) films decorated with gold nanoparticles (AuNPs) by cyclic voltammetry (CV). The prepared electrodes were named TATP-memory-GC/PCz/AuNPs (used for TATP determination) and HMTD-memory-GC/PCz/AuNPs (used for HMTD detection). The calibration lines of TATP and HMTD were found in the concentration range of 0.1-1.0 mg L-1 using the net current intensities of differential pulse voltammetry (DPV) versus analyte concentrations. The limit of detection (LOD) commonly found was 15 μg L-1 for TATP and HMTD. The sensor electrodes could separately determine intact TATP and HMTD in the presence of nitro-aromatic, nitramine, and nitrate ester energetic materials. The proposed electrochemical sensing method was not interfered by electroactive substances such as paracetamol, caffeine, acetylsalicylic acid, aspartame, d-glucose, and detergent (containing perborate and percarbonate) used as camouflage materials for PBEs. This is the first molecularly imprinted polymeric electrode for PBEs accomplishing such low LODs, and the DPV method was statistically validated in contaminated clay soil samples against the GC-MS method for TATP and a spectrophotometric method for HMTD using t- and F-tests.
URI
http://hdl.handle.net/20.500.12627/188357
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85143856915&origin=inward
https://doi.org/10.1021/acs.analchem.2c04450
Collections
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypes

My Account

LoginRegister

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV