Basit öğe kaydını göster

dc.contributor.authoremin, ilter
dc.contributor.authorSALİHOĞLU, ZİYA
dc.contributor.authorKöse, Yıldız
dc.contributor.authorDEMİRKIRAN, OKTAY
dc.contributor.authordemiroluk, sener
dc.date.accessioned2021-03-05T07:49:23Z
dc.date.available2021-03-05T07:49:23Z
dc.date.issued2004
dc.identifier.citationSALİHOĞLU Z., demiroluk s., DEMİRKIRAN O., emin i., Köse Y., "Effects of sevoflurane, propofol and position changes on respiratory mechanics", Middle East journal of anesthesiology., cilt.17, ss.811-818, 2004
dc.identifier.othervv_1032021
dc.identifier.otherav_95ba94a7-701e-4b5c-851d-d264399b1a36
dc.identifier.urihttp://hdl.handle.net/20.500.12627/100833
dc.description.abstractThis study was designed to investigate the effects of propofol, sevoflurane and position changes on respiratory mechanics. Forty patients scheduled for thyroid surgery were divided randomly into two groups; those receiving sevoflurane (group S) (n=20), and those receiving TIVA propofol (group P) (n=22). Dynamic compliance (Cdyn), peak inspiratory pressure (PIP), and respiratory resistance (Rr) values were recorded with a VenTrak respiratory monitor (Novometrix Inc. USA) at three time instances. The first measurement was done immediately after the beginning of ventilation and before the inhalation agent was initiated (Induction). Second measurement was done after 5 minutes of thyroid position (Thyroid) (ventilation with 1 MAC sevoflurane concentration or propofol infusion at the rate of 6 mg/kg/h). The third measurement was performed 5 minutes after end of surgery in the supine position (Supine) Blood gases were measured at the three time instances. Respiratory mechanics did not change in the P group (51 +/- 13, 46 +/- 11, 48 +/- 10 mL/cmH2O) at Induction, Thyroid and Supine positions). In the S group, dynamic compliance measurements showed changes statistically significant in the supine position (52 +/- 6 mL/cmH2O)) when compared to Induction (47 +/- 9 mL/cmH2O) and Thyroid position (47 +/- 6 mL/cmH2O) measurements (p<0.05). When the groups were compared with each other, there was no significant difference whatsoever at all periods (p>0.05). His concluded that sevoflurane, propofol and position changes exhibit similar effects on respiratory mechanics and blood gases at described dose and concentration.
dc.language.isoeng
dc.subjectSağlık Bilimleri
dc.subjectKlinik Tıp (MED)
dc.subjectTıp
dc.titleEffects of sevoflurane, propofol and position changes on respiratory mechanics
dc.typeMakale
dc.relation.journalMiddle East journal of anesthesiology.
dc.contributor.departmentDiğer Kurumlar , ,
dc.identifier.volume17
dc.identifier.issue5
dc.identifier.startpage811
dc.identifier.endpage818
dc.contributor.firstauthorID460977


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster