Show simple item record

dc.contributor.authorErdilek, Dina
dc.contributor.authorYazicioglu, Oktay
dc.contributor.authorGuray, Begum Efes
dc.contributor.authorGomec, Yavuz
dc.contributor.authorYaman, Batu Can
dc.contributor.authorDorter, Can
dc.date.accessioned2021-03-05T07:58:20Z
dc.date.available2021-03-05T07:58:20Z
dc.date.issued2012
dc.identifier.citationYaman B. C. , Guray B. E. , Dorter C., Gomec Y., Yazicioglu O., Erdilek D., "Effect of the erbium:yttrium-aluminum-garnet laser or diamond bur cavity preparation on the marginal microleakage of class V cavities restored with different adhesives and composite systems", LASERS IN MEDICAL SCIENCE, cilt.27, ss.785-794, 2012
dc.identifier.issn0268-8921
dc.identifier.otherav_96818563-29ca-43cc-916e-c6ac39b9a596
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/101316
dc.identifier.urihttps://doi.org/10.1007/s10103-011-0981-3
dc.description.abstractThe aim of this in vitro study was to compare the microleakage of Er:YAG laser and diamond bur on different bonding systems in class V restorations. Class V cavities were prepared with Er:YAG laser or diamond bur on 80 intact human molars. Teeth were randomly distributed into ten groups and cavities were restored with CeramX duo (DENTSPLY) or Filtek Silorane (3M/ESPE) using different bonding materials (One Coat 7.0 (ColtSne), XP Bond (DENTSPLY), Clearfil Protect Bond (Kuraray), AdperSE (3M/ESPE), and Silorane System Adhesive (3M/ESPE). All specimens were subjected to thermocycling and load cycling. After being immersed in silver nitrate dye, the specimens were sectioned. Microleakage was evaluated by stereomicroscope and SEM. Data were statistically analyzed by one-way ANOVA, Kruskal-Wallis, and Mann-Whitney tests. Statistically differences were found between groups (p > 0.05) and cavities prepared with the Er:YAG laser showed higher microleakage than diamond bur. The microleakage of different bonding systems was influenced by the choice of diamond bur or Er:YAG laser for class V composite cavity preparation.
dc.language.isoeng
dc.subjectCerrahi Tıp Bilimleri
dc.subjectBiyomedikal Mühendisliği
dc.subjectMühendislik ve Teknoloji
dc.subjectKlinik Tıp (MED)
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp
dc.subjectCERRAHİ
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, BİYOMEDİKSEL
dc.titleEffect of the erbium:yttrium-aluminum-garnet laser or diamond bur cavity preparation on the marginal microleakage of class V cavities restored with different adhesives and composite systems
dc.typeMakale
dc.relation.journalLASERS IN MEDICAL SCIENCE
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume27
dc.identifier.issue4
dc.identifier.startpage785
dc.identifier.endpage794
dc.contributor.firstauthorID30841


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record