Basit öğe kaydını göster

dc.contributor.authorMaki, Dennis G.
dc.contributor.authorAhmed, Altaf
dc.contributor.authorKanj, Souha S.
dc.contributor.authorChavarria Ugalde, Olber
dc.contributor.authorMapp, Trudell
dc.contributor.authorRaka, Lul
dc.contributor.authorMeng, Cheong Yuet
dc.contributor.authorLe Thi Anh Thu, Le Thi Anh Thu
dc.contributor.authorGhazal, Sameeh
dc.contributor.authorRosenthal, Victor D.
dc.contributor.authorHu Bijie, Hu Bijie
dc.contributor.authorRasslan, Ossama
dc.contributor.authorMehta, Yatin
dc.contributor.authorApisarnthanarak, Anucha
dc.contributor.authorMedeiros, Eduardo A.
dc.contributor.authorLeblebicioglu, Hakan
dc.contributor.authorFisher, Dale
dc.contributor.authorAlvarez-Moreno, Carlos
dc.contributor.authorAbu Khader, Ilham
dc.contributor.authorGonzalez Martinez, Marisela Del Rocio
dc.contributor.authorCuellar, Luis E.
dc.contributor.authorAnne Navoa-Ng, Josephine
dc.contributor.authorAbouqal, Redouane
dc.contributor.authorGuanche Garcell, Humberto
dc.contributor.authorMitrev, Zan
dc.contributor.authorPirez Garcia, Maria Catalina
dc.contributor.authorHamdi, Asma
dc.contributor.authorDuenas, Lourdes
dc.contributor.authorCancel, Elsie
dc.contributor.authorGurskis, Vaidotas
dc.contributor.authorGikas, Achilleas
dc.contributor.authorPazmino Narvaez, Leonardo
dc.contributor.authorMejia, Nepomuceno
dc.contributor.authorHadjieva, Nassya
dc.contributor.authorElanbya, May Osman Gamar
dc.contributor.authorGuzman Siritt, Maria Eugenia
dc.contributor.authorJayatilleke, Kushlani
dc.date.accessioned2021-03-05T08:32:53Z
dc.date.available2021-03-05T08:32:53Z
dc.date.issued2012
dc.identifier.citationRosenthal V. D. , Hu Bijie H. B. , Maki D. G. , Mehta Y., Apisarnthanarak A., Medeiros E. A. , Leblebicioglu H., Fisher D., Alvarez-Moreno C., Abu Khader I., et al., "International Nosocomial Infection Control Consortium (INICC) report, data summary of 36 countries, for 2004-2009", AMERICAN JOURNAL OF INFECTION CONTROL, cilt.40, ss.396-407, 2012
dc.identifier.issn0196-6553
dc.identifier.othervv_1032021
dc.identifier.otherav_996fd69c-39fb-4eab-b1e7-63fa14cb7f81
dc.identifier.urihttp://hdl.handle.net/20.500.12627/103188
dc.identifier.urihttps://doi.org/10.1016/j.ajic.2011.05.020
dc.description.abstractThe results of a surveillance study conducted by the International Nosocomial Infection Control Consortium (INICC) from January 2004 through December 2009 in 422 intensive care units (ICUs) of 36 countries in Latin America, Asia, Africa, and Europe are reported. During the 6-year study period, using Centers for Disease Control and Prevention (CDC) National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infections, we gathered prospective data from 313,008 patients hospitalized in the consortium's ICUs for an aggregate of 2,194,897 ICU bed-days. Despite the fact that the use of devices in the developing countries' ICUs was remarkably similar to that reported in US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were significantly higher in the ICUs of the INICC hospitals; the pooled rate of central line-associated bloodstream infection in the INICC ICUs of 6.8 per 1,000 central line-days was more than 3-fold higher than the 2.0 per 1,000 central line-days reported in comparable US ICUs. The overall rate of ventilator-associated pneumonia also was far higher (15.8 vs 3.3 per 1,000 ventilator-days), as was the rate of catheter-associated urinary tract infection (6.3 vs. 3.3 per 1,000 catheter-days). Notably, the frequencies of resistance of Pseudomonas aeruginosa isolates to imipenem (47.2% vs 23.0%), Klebsiella pneumoniae isolates to ceftazidime (76.3% vs 27.1%), Escherichia coli isolates to ceftazidime (66.7% vs 8.1%), Staphylococcus aureus isolates to methicillin (84.4% vs 56.8%), were also higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 7.3% (for catheter-associated urinary tract infection) to 15.2% (for ventilator-associated pneumonia). Copyright (C) 2011 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
dc.language.isoeng
dc.subjectSosyal ve Beşeri Bilimler
dc.subjectKAMU, ÇEVRE VE İŞ SAĞLIĞI
dc.subjectSosyal Bilimler Genel
dc.subjectSosyal Bilimler (SOC)
dc.subjectBULAŞICI HASTALIKLAR
dc.subjectİmmünoloji
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectSosyoloji
dc.subjectYaşam Bilimleri
dc.subjectTemel Bilimler
dc.titleInternational Nosocomial Infection Control Consortium (INICC) report, data summary of 36 countries, for 2004-2009
dc.typeMakale
dc.relation.journalAMERICAN JOURNAL OF INFECTION CONTROL
dc.contributor.departmentINICC , ,
dc.identifier.volume40
dc.identifier.issue5
dc.identifier.startpage396
dc.identifier.endpage407
dc.contributor.firstauthorID41760


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster