Basit öğe kaydını göster

dc.contributor.authorParlak, Mesut
dc.contributor.authorBozfakioǧlu, Yavuz
dc.contributor.authorAsoǧlu, Oktar
dc.contributor.authorMüslümanoǧlu, Mahmut
dc.contributor.authorIǧci, Abdullah
dc.contributor.authorYavuz, Ekrem
dc.contributor.authorMudun, Ayşe
dc.contributor.authorDilege, Ece
dc.contributor.authorÖzmen, Vahit
dc.contributor.authorKeçer, Mustafa
dc.date.accessioned2021-03-05T08:51:48Z
dc.date.available2021-03-05T08:51:48Z
dc.date.issued2003
dc.identifier.citationAsoǧlu O., Müslümanoǧlu M., Iǧci A., Özmen V., Keçer M., Parlak M., Bozfakioǧlu Y., Dilege E., Mudun A., Yavuz E., "The sentinel lymph node can be successfully detected by the usage of lymphoscintigraphy and gamma-probe in cases of breast cancer Meme kanserinde lenfosintigrafi ve gama prob kullanimi i̇le sentinel lenf nodülü başari i̇le tespít edilebilir", Turkish Journal of Surgery, cilt.19, ss.199-207, 2003
dc.identifier.issn1300-0705
dc.identifier.otherav_9b0e3ee4-60b8-4d11-aa41-2b26487296c6
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/104231
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=2442716534&origin=inward
dc.description.abstractThe existance of the metastatic axillary lymph node is the most important prognostic factor that plays role in the decision of the risk of invasion of the disease and in the decision of the adjuvant therapy. The aim of our study is to detect the sentinel lymph node (SLN) in early stage breast cancer cases by injecting radioactive colloid followed by the usage of the gamma-probe and to determine the relations between the pathological results of the ones of the SLN and the other axillary nodes. This study was performed on 54 cases of early stage breast cancer prospectively. Tc-99 m renium sulfur colloid under lymphoscintigraphy (0.5 milicurie) was injected to the quadrant of the site of the tumor subdermally and scintigraphic spots were taken afterwards. Following the detection of the SLN by the help of the gamma-probe, standard axillary dissection (Level 1-2) was applied to the patient. The results were observed in concepts of overall accuracy, false-negative rate, identification rate. Among the 54 cases that were included in this study 42 (77.8%) cases were Stage I and 12 (22.2%) cases were Stage II. The tumor was localized in the lateral quadrants in 34 (62%), and in the medial quadrants in 15 (27%) of the cases. Axillary drainage was detected in 52 cases (96%) and in 47 (87%) of these cases drainage was detected to be only to the axilla. In 2 (3.7%) cases drainage was detected to be only to the mammaria interna. The mean number of SLN detected in our study was 2.27. In 42% of our cases only a single node was detected. The detectability of the SLN by the gamma-probe is 98.15%. The false negative ratio is 5.3%. The SLN gives the same results with axillary dissection. There should be a small false negative ratio in order to rely on SLN biopsy.
dc.language.isoeng
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectCERRAHİ
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectCerrahi Tıp Bilimleri
dc.subjectSurgery
dc.subjectHealth Sciences
dc.titleThe sentinel lymph node can be successfully detected by the usage of lymphoscintigraphy and gamma-probe in cases of breast cancer Meme kanserinde lenfosintigrafi ve gama prob kullanimi i̇le sentinel lenf nodülü başari i̇le tespít edilebilir
dc.typeMakale
dc.relation.journalTurkish Journal of Surgery
dc.contributor.departmentIstanbul Üniversitesi Tıp Fakültesi , ,
dc.identifier.volume19
dc.identifier.issue4
dc.identifier.startpage199
dc.identifier.endpage207
dc.contributor.firstauthorID2494869


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster