Basit öğe kaydını göster

dc.contributor.authorNigdeli, SİNAN MELİH
dc.contributor.authorBoduroglu, M. Hasan
dc.date.accessioned2021-03-05T12:18:32Z
dc.date.available2021-03-05T12:18:32Z
dc.date.issued2013
dc.identifier.citationNigdeli S. M. , Boduroglu M. H. , "Active Tendon Control of Torsionally Irregular Structures under Near-Fault Ground Motion Excitation", COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, cilt.28, ss.718-736, 2013
dc.identifier.issn1093-9687
dc.identifier.othervv_1032021
dc.identifier.otherav_ac80c5d2-203f-4157-9e0e-01965993519f
dc.identifier.urihttp://hdl.handle.net/20.500.12627/115120
dc.identifier.urihttps://doi.org/10.1111/mice.12046
dc.description.abstractIn this study, torsionally irregular single-story and multistory structures under the effect of near-fault ground motion excitation were controlled by active tendons. Near-fault ground motions contain two impulsive characters. These impulsive characters are the directivity effect perpendicular to fault and the flint step parallel to fault. The structural models were simulated under bidirectional earthquake records superimposed with impulsive motions to examine the response of active control under near-fault effects. Also, the structures were analyzed only under the effect of bidirectional impulsive pulses. The control signals were obtained by Proportional-Integral-Derivative (PID) type controllers and the parameters of the controllers were obtained by using a numerical algorithm depending on time domain analyses. Time delay effect was also considered for active control system. Different cases of orientation of active tendons were examined and the results of the single-story structure were compared with another control strategy using frequency domain responses in the optimization process. As a conclusion, the control concept is significantly effective on reducing maximum responses in translational and rotational directions and obtaining a steady-state response.
dc.language.isoeng
dc.subjectYapı
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, SİVİL
dc.subjectULAŞIM BİLİMİ VE TEKNOLOJİSİ
dc.subjectULAŞIM
dc.subjectBilgisayar Bilimleri
dc.subjectBilgisayar Grafiği
dc.subjectBİLGİSAYAR BİLİMİ, İNTERDİSİPLİNER UYGULAMALAR
dc.subjectBilgisayar Bilimi
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectİnşaat Mühendisliği
dc.subjectİNŞAAT VE YAPI TEKNOLOJİSİ
dc.subjectMühendislik ve Teknoloji
dc.titleActive Tendon Control of Torsionally Irregular Structures under Near-Fault Ground Motion Excitation
dc.typeMakale
dc.relation.journalCOMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume28
dc.identifier.issue9
dc.identifier.startpage718
dc.identifier.endpage736
dc.contributor.firstauthorID82110


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster