Basit öğe kaydını göster

dc.contributor.authorErgin, R. N.
dc.contributor.authorErgin, A. S.
dc.contributor.authorYayla, M.
dc.date.accessioned2021-03-05T12:31:59Z
dc.date.available2021-03-05T12:31:59Z
dc.date.issued2013
dc.identifier.citationErgin R. N. , Yayla M., Ergin A. S. , "Practical biometric ratios of first-trimester screening", CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, cilt.40, ss.106-108, 2013
dc.identifier.issn0390-6663
dc.identifier.othervv_1032021
dc.identifier.otherav_ad9b1a28-d8b0-4952-a82c-50568d909eba
dc.identifier.urihttp://hdl.handle.net/20.500.12627/115834
dc.description.abstractPurpose: The authors aimed to determine some practical contributive biometry ratios of the first trimester screening in order to note more accurate measurements and recognize abnormal/mistaken measurements. Materials and Methods: All medical records of singleton pregnancies whose first-trimester screening that was performed between the years of 2004-2010, were evaluated retrospectively. Singleton pregnancies with detected/suspicious anatomical or genetic fetal anomalies, any systemic disease, and familial genetic diseases were excluded. The following ratios were calculated and compared: measurements of biparietal diameter [BPD], head circumference [HC], abdominal circumference [AC], femur length [FL], and crown rump length [CRL] of included fetuses, to each other were calculated. Mean and standard deviations of the ratios were determined for each gestational weeks of 11(0.6), 12(0-6), and 13(0.6). Results: A total of 1,615 singleton pregnancies were included in the data analyses according to exclusion and inclusion criteria. Mean maternal age was 29.5 +/- 4.6 years. Mean gestational age of the fetuses was 12.6 +/- 0.6 weeks. Mean and standard deviation of the ratios were as follows; CRL/BPD: 3.0 +/- 0.2; AC/BPD: 3.0 +/- 0.2; CRL/AC: 1.0 +/- 0.1; CRL/HC: 0.8 +/- 0.1; CRL/FL: 8.8 +/- 1.6; BPD/FL: 2.9 +/- 0.6; AC/FL: 8.9 +/- 1.6; HC/FL: 11.1 +/- 2.2, and HC/AC: 1.3 +/- 0.1. Among these ratios the standard deviation was small in the ratios of CRL/BPD, AC/BPD, CRL/AC, CRL/HC, and HC/AC. The equations of these ratios were derived from linear regression analyses. The AC/BPD, and CRL/AC ratios had lower R2 values than others, indicating a rather constant ratio. Conclusions: The ratios of CRL/BPD, AC/BPD, and CRL/AC seem more practical to be used in the first-trimester fetal ultrasonography practice.
dc.language.isoeng
dc.subjectTıp
dc.subjectKadın Hastalıkları ve Doğum
dc.subjectSağlık Bilimleri
dc.subjectCerrahi Tıp Bilimleri
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectKADIN HASTALIKLARI & DOĞUM
dc.titlePractical biometric ratios of first-trimester screening
dc.typeMakale
dc.relation.journalCLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY
dc.contributor.departmentBayindir Health Group , ,
dc.identifier.volume40
dc.identifier.issue1
dc.identifier.startpage106
dc.identifier.endpage108
dc.contributor.firstauthorID207780


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster