Basit öğe kaydını göster

dc.contributor.authorOzen, Y.
dc.contributor.authorDurukan, I. Kars
dc.contributor.authorCaliskan, S.
dc.contributor.authorCete, S.
dc.contributor.authorCevrimli, B. S.
dc.contributor.authorOzcelik, S.
dc.contributor.authorMemmedli, T.
dc.contributor.authorKinaci, Barış
dc.contributor.authorOzturk, M. K.
dc.contributor.authorCorekci, S.
dc.date.accessioned2021-03-05T12:41:05Z
dc.date.available2021-03-05T12:41:05Z
dc.date.issued2014
dc.identifier.citationDurukan I. K. , Caliskan S., Cete S., Cevrimli B. S. , Kinaci B., Ozen Y., Corekci S., Ozturk M. K. , Memmedli T., Ozcelik S., "Preparation of RF sputtered AZO/Au thin film hydrogen peroxide sensitive electrode for utilization as a biosensor", JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, cilt.25, ss.3154-3159, 2014
dc.identifier.issn0957-4522
dc.identifier.otherav_ae54ca68-9b64-4c6f-9a2e-967a3d7b34cb
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/116316
dc.identifier.urihttps://doi.org/10.1007/s10854-014-1997-9
dc.description.abstractIn this study, hydrogen peroxide (H2O2) sensitive Al doped ZO(AZO)/Au thin film electrode has been developed for the utilization as a biosensor. A preferred c-axis oriented AZO/Au thin film was deposited on quartz substrate by RF magnetron sputtering at room temperature. Structural, morphological and optical properties of the AZO film were analyzed by X-ray diffraction, atomic force microscopy and photoluminescence. The sensor performance was characterized by electrochemical analysis device. The sensibility of prepared thin film electrodes to H2O2 was studied. The dependence of amperometric response current on the glucose and cholesterol concentrations was also investigated.
dc.language.isoeng
dc.subjectFİZİK, YOĞUN MADDE
dc.subjectMÜHENDİSLİK, ELEKTRİK VE ELEKTRONİK
dc.subjectMühendislik
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMALZEME BİLİMİ, MULTIDISCIPLINARY
dc.subjectMalzeme Bilimi
dc.subjectFİZİK, UYGULAMALI
dc.subjectFizik
dc.subjectTemel Bilimler (SCI)
dc.subjectBilgi Sistemleri, Haberleşme ve Kontrol Mühendisliği
dc.subjectSinyal İşleme
dc.subjectTemel Bilimler
dc.subjectYoğun Madde 1:Yapısal, Mekanik ve Termal Özellikler
dc.subjectMühendislik ve Teknoloji
dc.titlePreparation of RF sputtered AZO/Au thin film hydrogen peroxide sensitive electrode for utilization as a biosensor
dc.typeMakale
dc.relation.journalJOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS
dc.contributor.departmentEskişehir Osmangazi Üniversitesi , ,
dc.identifier.volume25
dc.identifier.issue7
dc.identifier.startpage3154
dc.identifier.endpage3159
dc.contributor.firstauthorID92532


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster