Basit öğe kaydını göster

dc.contributor.authorCanat, Halil Lutfi
dc.contributor.authorAltunrende, Fatih
dc.contributor.authorOzkuvanci, Unsal
dc.contributor.authorAtalay, Hasan Anil
dc.contributor.authorUlker, Volkan
dc.contributor.authorAlkan, Ilter
dc.date.accessioned2021-03-05T13:02:38Z
dc.date.available2021-03-05T13:02:38Z
dc.date.issued2016
dc.identifier.citationAtalay H. A. , Ulker V., Alkan I., Canat H. L. , Ozkuvanci U., Altunrende F., "Impact of Three-Dimensional Printed Pelvicaliceal System Models on Residents' Understanding of Pelvicaliceal System Anatomy Before Percutaneous Nephrolithotripsy Surgery: A Pilot Study", JOURNAL OF ENDOUROLOGY, cilt.30, ss.1132-1137, 2016
dc.identifier.issn0892-7790
dc.identifier.othervv_1032021
dc.identifier.otherav_b0321c50-1ca9-454d-8e48-5bd00be25dff
dc.identifier.urihttp://hdl.handle.net/20.500.12627/117483
dc.identifier.urihttps://doi.org/10.1089/end.2016.0307
dc.description.abstractObjective: To investigate the impact of three-dimensional (3D) printed pelvicaliceal system models on residents' understanding of pelvicaliceal system anatomy before percutaneous nephrolithotripsy (PCNL). Materials and Methods: Patients with unilateral complex renal stones indicating PCNL were selected. Usable data of patients were obtained from CT-scans in Digital Imaging and Communications in Medicine (DICOM) format. Mimics software version 16.0 (Materialise, Belgium) was used for segmentation and extraction of pelvicaliceal systems (PCSs). All DICOM-formatted files were converted to the stereolithography file format. Finally, fused deposition modeling was used to create plasticine 3D models of PCSs. A questionnaire was designed so that residents could assess the 3D models' effects on their understanding of the anatomy of the pelvicaliceal system before PCNL (Fig. 3). Results: Five patients' anatomically accurate models of the human renal collecting system were effectively generated (Figs. 1 and 2). After presentation of the 3D models, residents were 86% and 88% better at determining the number of anterior and posterior calices, respectively, 60% better at understanding stone location, and 64% better at determining optimal entry calix into the collecting system (Fig. 5). Conclusion: Generating kidney models of PCSs using 3D printing technology is feasible, and the models were accepted by residents as aids in surgical planning and understanding of pelvicaliceal system anatomy before PCNL.
dc.language.isoeng
dc.subjectKlinik Tıp
dc.subjectÜROLOJİ VE NEFROLOJİ
dc.subjectKlinik Tıp (MED)
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectDahili Tıp Bilimleri
dc.subjectİç Hastalıkları
dc.subjectNefroloji
dc.titleImpact of Three-Dimensional Printed Pelvicaliceal System Models on Residents' Understanding of Pelvicaliceal System Anatomy Before Percutaneous Nephrolithotripsy Surgery: A Pilot Study
dc.typeMakale
dc.relation.journalJOURNAL OF ENDOUROLOGY
dc.contributor.departmentIstanbul Okmeydani Training & Research Hospital , ,
dc.identifier.volume30
dc.identifier.issue10
dc.identifier.startpage1132
dc.identifier.endpage1137
dc.contributor.firstauthorID235421


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster