Basit öğe kaydını göster

dc.contributor.authorKaraali, S.
dc.contributor.authorBilir, S.
dc.contributor.authorGökçe, E. Yaz
dc.date.accessioned2021-03-05T15:42:00Z
dc.date.available2021-03-05T15:42:00Z
dc.identifier.citationKaraali S., Gökçe E. Y. , Bilir S., "Photometric calibration of the [alpha/Fe] element: I. Calibration with U BV photometry", ASTROPHYSICS AND SPACE SCIENCE, cilt.361, 2016
dc.identifier.issn0004-640X
dc.identifier.othervv_1032021
dc.identifier.otherav_bd1169ea-dbbb-4f57-9ab4-e2579dd8b04f
dc.identifier.urihttp://hdl.handle.net/20.500.12627/125662
dc.identifier.urihttps://doi.org/10.1007/s10509-016-2928-4
dc.description.abstractWe present the calibration of the [alpha/Fe] element in terms of the ultra-violet excess for 469 dwarf stars with 0.325 < (B -V)(0) <= 0.775 mag corresponding to the spectral type range F0-K2. The star sample is separated into nine sub-samples with equal range in (B -V)(0) colour, Delta(B-V)(0) = 0.05 mag, and a third degree polynomial is fitted to each dataset. Our calibrations provide [alpha/Fe] elements in the range [0.0, 0.4]. We applied the procedure to two sets of field stars and two sets of clusters. The mean and the corresponding standard deviation of the residuals for 43 field stars taken from the Hypatia catalogue are [alpha/Fe] = -0.090 and sigma = 0.102 dex, while for the 39 ones taken from the same catalogue of stars used in the calibration these quantities are [alpha/Fe] = -0.009 and sigma = 0.079 dex, respectively. We showed that the differences between the mean of the residuals and standard deviations for two sets of clusters ([alpha/Fe] = 0.073 and sigma = 0.91 dex; [alpha/Fe] = -0.012 and sigma = 0.053 dex) originate from the (B - V)(0) and (U - B)(0) colour indices of the clusters which are taken from different sources. The differences between the original [alpha/Fe] elements and the estimated ones (the residuals) are compatible with the uncertainties in the literature. Also, there is good agreement between the distribution of the synthetic alpha elements versus ultra-violet excesses and the ones obtained via our calibrations.
dc.language.isoeng
dc.subjectTemel Bilimler
dc.subjectAstronomi ve Astrofizik
dc.subjectFizik
dc.subjectTemel Bilimler (SCI)
dc.subjectUzay bilimi
dc.subjectASTRONOMİ VE ASTROFİZİK
dc.titlePhotometric calibration of the [alpha/Fe] element: I. Calibration with U BV photometry
dc.typeMakale
dc.relation.journalASTROPHYSICS AND SPACE SCIENCE
dc.contributor.departmentİstanbul Üniversitesi , Fen Fakültesi , Astronomi Ve Uzay Bilimleri Bölümü
dc.identifier.volume361
dc.contributor.firstauthorID2210887


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster