dc.contributor.author | TEKÇE, NESLİHAN | |
dc.contributor.author | Tuncer, Safa | |
dc.contributor.author | Demirci, Mustafa | |
dc.contributor.author | Pala, Kansad | |
dc.date.accessioned | 2021-03-05T16:03:02Z | |
dc.date.available | 2021-03-05T16:03:02Z | |
dc.date.issued | 2016 | |
dc.identifier.citation | TEKÇE N., Pala K., Demirci M., Tuncer S., "Influence of different composite materials and cavity preparation designs on the fracture resistance of mesio-occluso-distal inlay restoration", DENTAL MATERIALS JOURNAL, cilt.35, ss.523-531, 2016 | |
dc.identifier.issn | 0287-4547 | |
dc.identifier.other | av_becba7da-fc4c-438e-8eb9-b7d427071b58 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/126701 | |
dc.identifier.uri | https://doi.org/10.4012/dmj.2015-287 | |
dc.description.abstract | The aim of the study to evaluate the fracture resistance of a computer-aided design/computer-aided manufacturing (CAD/CAM) and three indirect composite materials for three different mesio-occluso-distal (MOD) inlay cavity designs. A total of 120 mandibular third molar were divided into three groups: (G1) non-proximal box, (G2) 2-mm proximal box, and (G3) 4-mm proximal box. Each cavity design received four composite materials: Estenia, Epricord (Kuraray, Japan), Tescera (Bisco, USA), and Cerasmart CAD/CAM blocks (GC, USA). The specimens were subjected to a compressive load at a crosshead speed of 1 mm/min. The data was analyzed using the two-way analysis of variance and Bonferroni post hoc test (p<0.05). Estenia exhibited significantly higher fracture strength than Epricord and Cerasmart in G1. In G2 and G3, there was no significant difference among the four materials. Using a non-proximal box design for the cavity can improve the fracture resistance of the inlay restoration. | |
dc.language.iso | eng | |
dc.subject | Diş Hekimliği | |
dc.subject | Mühendislik ve Teknoloji | |
dc.subject | Mühendislik, Bilişim ve Teknoloji (ENG) | |
dc.subject | Sağlık Bilimleri | |
dc.subject | Tıp | |
dc.subject | Malzeme Bilimi | |
dc.subject | MALZEME BİLİMİ, BİYOMATERYAL | |
dc.subject | Klinik Tıp (MED) | |
dc.subject | Klinik Tıp | |
dc.subject | DİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP | |
dc.title | Influence of different composite materials and cavity preparation designs on the fracture resistance of mesio-occluso-distal inlay restoration | |
dc.type | Makale | |
dc.relation.journal | DENTAL MATERIALS JOURNAL | |
dc.contributor.department | Erciyes Üniversitesi , , | |
dc.identifier.volume | 35 | |
dc.identifier.issue | 3 | |
dc.identifier.startpage | 523 | |
dc.identifier.endpage | 531 | |
dc.contributor.firstauthorID | 47850 | |