Basit öğe kaydını göster

dc.contributor.authorTEKÇE, NESLİHAN
dc.contributor.authorTuncer, Safa
dc.contributor.authorDemirci, Mustafa
dc.contributor.authorPala, Kansad
dc.date.accessioned2021-03-05T16:03:02Z
dc.date.available2021-03-05T16:03:02Z
dc.date.issued2016
dc.identifier.citationTEKÇE N., Pala K., Demirci M., Tuncer S., "Influence of different composite materials and cavity preparation designs on the fracture resistance of mesio-occluso-distal inlay restoration", DENTAL MATERIALS JOURNAL, cilt.35, ss.523-531, 2016
dc.identifier.issn0287-4547
dc.identifier.otherav_becba7da-fc4c-438e-8eb9-b7d427071b58
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/126701
dc.identifier.urihttps://doi.org/10.4012/dmj.2015-287
dc.description.abstractThe aim of the study to evaluate the fracture resistance of a computer-aided design/computer-aided manufacturing (CAD/CAM) and three indirect composite materials for three different mesio-occluso-distal (MOD) inlay cavity designs. A total of 120 mandibular third molar were divided into three groups: (G1) non-proximal box, (G2) 2-mm proximal box, and (G3) 4-mm proximal box. Each cavity design received four composite materials: Estenia, Epricord (Kuraray, Japan), Tescera (Bisco, USA), and Cerasmart CAD/CAM blocks (GC, USA). The specimens were subjected to a compressive load at a crosshead speed of 1 mm/min. The data was analyzed using the two-way analysis of variance and Bonferroni post hoc test (p<0.05). Estenia exhibited significantly higher fracture strength than Epricord and Cerasmart in G1. In G2 and G3, there was no significant difference among the four materials. Using a non-proximal box design for the cavity can improve the fracture resistance of the inlay restoration.
dc.language.isoeng
dc.subjectDiş Hekimliği
dc.subjectMühendislik ve Teknoloji
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectMalzeme Bilimi
dc.subjectMALZEME BİLİMİ, BİYOMATERYAL
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.titleInfluence of different composite materials and cavity preparation designs on the fracture resistance of mesio-occluso-distal inlay restoration
dc.typeMakale
dc.relation.journalDENTAL MATERIALS JOURNAL
dc.contributor.departmentErciyes Üniversitesi , ,
dc.identifier.volume35
dc.identifier.issue3
dc.identifier.startpage523
dc.identifier.endpage531
dc.contributor.firstauthorID47850


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster