Basit öğe kaydını göster

dc.contributor.authorBural, Canan
dc.contributor.authorGeckili, Onur
dc.contributor.authorBilmenoglu, Caglar
dc.contributor.authorBilhan, Hakan
dc.contributor.authorCilingir, Altug
dc.date.accessioned2021-03-05T16:09:34Z
dc.date.available2021-03-05T16:09:34Z
dc.date.issued2015
dc.identifier.citationGeckili O., Cilingir A., Bural C., Bilmenoglu C., Bilhan H., "Determination of the Optimum Torque to Tighten the Smartpegs of Magnetic Resonance Frequency Analyses Devices: An Ex Vivo Study", JOURNAL OF ORAL IMPLANTOLOGY, cilt.41, 2015
dc.identifier.issn0160-6972
dc.identifier.otherav_bf3c6797-57e0-4efb-b241-0633ea8fc900
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/126998
dc.identifier.urihttps://doi.org/10.1563/aaid-joi-d-14-00266
dc.description.abstractThe aim of this study was to find an optimal value for tightening the Smartpegs for magnetic radiofrequency analysis devices (RFAs) devices. Thirty implants were placed in 3 cow ribs. The RFA value of each implant was measured in buccal and mesial directions after tightening the Smartpegs with 1, 3, 4, 8, 9, 10, and 11 Ncm. Additionally, 4 different examiners measured the RFA after hand tightening the Smartpegs, and the results were compared. The buccal implant stability quotient (ISQ) values when the Smartpegs were tightened to 1Ncm were significantly lower than the ISQ values when the Smartpegs were tightened to 3, 4, 8, 9, 10, and 11 Ncm (P<.05). The mesial ISQ values when the Smartpegs were tightened to 1, 3, and 4 Ncm were significantly lower than the ISQ values when the Smartpegs were tightened with higher torque values (P<.05). The buccal measurements made by 1 examiner was significantly lower than 3 Ncm (P<.05), and the buccal measurements made by 1 examiner was significantly lower than 4 Ncm (P<.05). The mesial ISQ values measured by 2 examiners were significantly lower than 3 Ncm (P<.05), and the mesial ISQ values measured by the other 2 examiners were significantly lower than 8 Ncm (P<.05). The tightening of the Smartpegs should be standardized by the manufacturer to a range of 5-8 Ncm in order to gain reliable objective RFA values, instead of leaving it to subjective finger pressure.
dc.language.isoeng
dc.subjectKlinik Tıp
dc.subjectDiş Hekimliği
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.titleDetermination of the Optimum Torque to Tighten the Smartpegs of Magnetic Resonance Frequency Analyses Devices: An Ex Vivo Study
dc.typeMakale
dc.relation.journalJOURNAL OF ORAL IMPLANTOLOGY
dc.contributor.departmentTrakya Üniversitesi , ,
dc.identifier.volume41
dc.identifier.issue6
dc.contributor.firstauthorID73165


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster