Basit öğe kaydını göster

dc.contributor.authorAydin, Muhammed
dc.contributor.authorZazoglu, Sinan
dc.contributor.authorAnilanmert, Beril
dc.contributor.authorCengiz, Salih
dc.date.accessioned2021-03-05T16:31:21Z
dc.date.available2021-03-05T16:31:21Z
dc.date.issued2017
dc.identifier.citationZazoglu S., Anilanmert B., Aydin M., Cengiz S., "Fast Confirmation for Marijuana Metabolite: THC-COOH, Ultra-Fast LC-MS/MS Run Time, and Application to Routine Samples", ACTA CHROMATOGRAPHICA, cilt.29, ss.253-265, 2017
dc.identifier.issn1233-2356
dc.identifier.othervv_1032021
dc.identifier.otherav_c10ef17b-eeb6-40d9-91c8-9bdcecf31449
dc.identifier.urihttp://hdl.handle.net/20.500.12627/128133
dc.identifier.urihttps://doi.org/10.1556/1326.2017.29.2.09
dc.description.abstractA fast, reliable, inexpensive, and practical method with a low determination limit and high recovery has been developed for the determination of the marijuana metabolite in routine analysis. THC-COOH in urine was validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Before an easy single-step extraction with Toxi-Tubes, basic hydrolysis was performed at 60 degrees C for 30 min. LC-MS/MS analysis takes 2.5 min for each sample, and the retention time of the analyte is 1.75 min. Specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, repeatability, and intermediate precision (inter-day) system suitability parameters were determined in the validation study. The recovery of the extraction method was 88.67 (+/-5.91). LOD and LOQ values were 1.41 and 5.00 ng mL(-1), respectively. The method showed linear response between the values 5.00 and 500.00 ng mL(-1). The repeatability was 9.64% (relative standard deviation, RSD%), and the intermediate precisions (RSDR%) were 10.73%, 13.74%, and 8.11% at 10.00, 100.00, and 200.00 ng mL(-1) concentration levels, respectively. No statistically significant difference was found in ANOVA analysis, between three consecutive days in intermediate precision study, for 90% confidence level. HorRat values were between 0.34 and 0.61. The method was applied to CEDIA positive samples, obtained from the Trabzon Group Presidency of Turkish Council of Forensic Medicine, successfully.
dc.language.isoeng
dc.subjectTemel Bilimler
dc.subjectAnalitik Kimya
dc.subjectTemel Bilimler (SCI)
dc.subjectKimya
dc.subjectKİMYA, ANALİTİK
dc.titleFast Confirmation for Marijuana Metabolite: THC-COOH, Ultra-Fast LC-MS/MS Run Time, and Application to Routine Samples
dc.typeMakale
dc.relation.journalACTA CHROMATOGRAPHICA
dc.contributor.departmentMinistry of Justice - Turkey , ,
dc.identifier.volume29
dc.identifier.issue2
dc.identifier.startpage253
dc.identifier.endpage265
dc.contributor.firstauthorID243196


Bu öğenin dosyaları: