Basit öğe kaydını göster

dc.contributor.authorUzer, Aysem
dc.contributor.authorCan, Ziya
dc.contributor.authorTurkekul, Kader
dc.contributor.authorApak, Resat
dc.contributor.authorErcag, Erol
dc.date.accessioned2021-03-02T22:14:43Z
dc.date.available2021-03-02T22:14:43Z
dc.date.issued2015
dc.identifier.citationCan Z., Uzer A., Turkekul K., Ercag E., Apak R., "Determination of Triacetone Triperoxide with a N,N-Dimethyl-p-phenylenediamine Sensor on Nafion Using Fe3O4 Magnetic Nanoparticles", ANALYTICAL CHEMISTRY, cilt.87, sa.19, ss.9589-9594, 2015
dc.identifier.issn0003-2700
dc.identifier.othervv_1032021
dc.identifier.otherav_0b9248f2-59a1-4f76-84b4-1b02f9015cc1
dc.identifier.urihttp://hdl.handle.net/20.500.12627/13457
dc.identifier.urihttps://doi.org/10.1021/acs.analchem.5b01775
dc.description.abstractThe explosive triacetone triperoxide (TATP) can be easily manufactured from readily accessible reagents and is extremely difficult to detect, owing to the lack of UV absorbance, fluorescence, or facile ionization. The developed method is based on the acidic hydrolysis of TATP into H2O2 pH adjustment to 3.6, and the addition of magnetite nanoparticles (Fe3O4 MNPs) to the medium to produce hydroxyl radicals from H2O2, owing to the peroxidase-like activity of MNPs. The formed radicals converted the N,N-dimethyl-p-phenylenediamine (DMPD) probe to the colored DMPD radical cation, the optical absorbance of which was measured at a wavelength of 554 nm. The molar absorptivity (epsilon) of the method for TATP was 21.06 x 10(3) L mol(-1) cm(-1). The colored DMPD+ product in solution could be completely retained on a cation-exchanger Nafion membrane, constituting a colorimetric sensor for TATP and increasing the analytical sensitivity. The proposed method did not respond to a number of hand luggage items like detergent, sweetener, sugar, acetylsalicylic acid (aspirin), and paracetamol-caffeine-based analgesic drugs. On the other hand, TATP could be almost quantitatively recovered from a household detergent and sweetener that can be used as camouflage for the analyte. Neither common soil and groundwater ions (e.g., Ca2+, Mg2+, K+, Cl-, SO42-, and NO3-) at 100-fold ratios nor nitro-explosives of trinitrotoluene (TNT), hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), and pentaerythritol tetranitrate (PETN) at 10-fold amounts interfered with the proposed assay. The method was statistically validated against the standard GC/MS reference method.
dc.language.isoeng
dc.subjectKimya
dc.subjectKİMYA, ANALİTİK
dc.subjectTemel Bilimler
dc.subjectAnalitik Kimya
dc.subjectTemel Bilimler (SCI)
dc.titleDetermination of Triacetone Triperoxide with a N,N-Dimethyl-p-phenylenediamine Sensor on Nafion Using Fe3O4 Magnetic Nanoparticles
dc.typeMakale
dc.relation.journalANALYTICAL CHEMISTRY
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume87
dc.identifier.issue19
dc.identifier.startpage9589
dc.identifier.endpage9594
dc.contributor.firstauthorID11415


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster