Show simple item record

dc.contributor.authorAsik, M
dc.contributor.authorSener, N
dc.date.accessioned2021-03-05T18:53:17Z
dc.date.available2021-03-05T18:53:17Z
dc.date.issued2002
dc.identifier.citationAsik M., Sener N., "Failure strength of repair devices versus meniscus suturing techniques", KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, cilt.10, ss.25-29, 2002
dc.identifier.issn0942-2056
dc.identifier.otherav_cc994a1b-ac52-4f67-907d-8f06d0edfce2
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/135438
dc.identifier.urihttps://doi.org/10.1007/s001670100247
dc.description.abstractThe purpose of this study was to compare the load to failure of different common suturing techniques with repair devices. Seventy-one calf medial menisci were cut to simulate peripheral longitudinal tears and repaired with one of 13 repair techniques. The two parts of the meniscus were pulled using the Instron tensometer until failure occurred. The techniques and repair devices tested were vertical (0 PDS, 2-0 PDS, 2-0 Ethibond), horizontal (0 PDS, 2-0 PDS, 2-0 Ethibond) suturing, T-fix, Mitek, Clearfix screw, Clearfix dart, Biostinger, S-D-sorb, and Artrex dart. The strongest repair method in our study was the vertical sutures with 0 PDS. In this study the mean failure strength of all meniscal repair devices was lower than that of the vertical and horizontal suturing techniques. All meniscus repair devices except T-fix and in some the Arthrex dart (40% broken up) pulled out of the menisci. Devices which had only horizontally placed barbs had lower mean failure strength. Failure strength of T-fix was similar to horizontal sutures with 2-0 Ethibond and 2-0 PDS. In conclusion, because all meniscal repair devices had inferior results, when such devices are used, postoperative rehabilitation should not be hastened, and their inferior primary stability should be kept in mind.
dc.language.isoeng
dc.subjectSosyal Bilimler (SOC)
dc.subjectCERRAHİ
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectCerrahi Tıp Bilimleri
dc.subjectOrtopedi ve Travmatoloji
dc.subjectSosyal ve Beşeri Bilimler
dc.subjectSosyoloji
dc.subjectSosyal Bilimler Genel
dc.subjectSPOR BİLİMLERİ
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectORTOPEDİ
dc.titleFailure strength of repair devices versus meniscus suturing techniques
dc.typeMakale
dc.relation.journalKNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
dc.contributor.department, ,
dc.identifier.volume10
dc.identifier.issue1
dc.identifier.startpage25
dc.identifier.endpage29
dc.contributor.firstauthorID164074


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record