Basit öğe kaydını göster

dc.contributor.authorCamci, E
dc.contributor.authorAkinci, Ozan
dc.contributor.authorErgin, P
dc.contributor.authorTugrul, M
dc.contributor.authorCakar, Nahit
dc.contributor.authorTurnaoglu, S
dc.date.accessioned2021-03-05T20:20:55Z
dc.date.available2021-03-05T20:20:55Z
dc.date.issued2001
dc.identifier.citationTurnaoglu S., Tugrul M., Camci E., Cakar N., Akinci O., Ergin P., "Clinical applicability of the substitution of mixed venous oxygen saturation with central venous oxygen saturation.", Journal of cardiothoracic and vascular anesthesia, cilt.15, ss.574-9, 2001
dc.identifier.issn1053-0770
dc.identifier.othervv_1032021
dc.identifier.otherav_d3c6601f-9994-4b21-8c56-3a5523778c3f
dc.identifier.urihttp://hdl.handle.net/20.500.12627/139777
dc.identifier.urihttps://doi.org/10.1053/jcan.2001.26534
dc.description.abstractObjective: To examine the clinical applicability of substituting central venous oxygen saturation (ScvO(2)) for mixed venous oxygen saturation (SmvO(2)) in monitoring global tissue oxygenation.
dc.language.isoeng
dc.subjectDahili Tıp Bilimleri
dc.subjectGöğüs Hastalıkları ve Allerji
dc.subjectKardiyoloji
dc.subjectCerrahi Tıp Bilimleri
dc.subjectAnesteziyoloji
dc.subjectPERİFERAL VASKÜLER HASTALIĞI
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectSOLUNUM SİSTEMİ
dc.subjectCARDIAC ve CARDIOVASCULAR SİSTEMLER
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectANESTEZİYOLOJİ
dc.titleClinical applicability of the substitution of mixed venous oxygen saturation with central venous oxygen saturation.
dc.typeMakale
dc.relation.journalJournal of cardiothoracic and vascular anesthesia
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume15
dc.identifier.issue5
dc.identifier.startpage574
dc.identifier.endpage9
dc.contributor.firstauthorID27104