Basit öğe kaydını göster

dc.contributor.authorChuckpaiwong, Bavornrit
dc.contributor.authorOgut, Tahir
dc.contributor.authorEasley, Mark E.
dc.contributor.authorLe, Ian L. D.
dc.contributor.authorGlisson, Richard R.
dc.date.accessioned2021-03-05T20:23:20Z
dc.date.available2021-03-05T20:23:20Z
dc.date.issued2009
dc.identifier.citationOgut T., Glisson R. R. , Chuckpaiwong B., Le I. L. D. , Easley M. E. , "External Ring Fixation Versus Screw Fixation for Ankle Arthrodesis: A Biomechanical Comparison", FOOT & ANKLE INTERNATIONAL, cilt.30, ss.353-360, 2009
dc.identifier.issn1071-1007
dc.identifier.otherav_d3ef14ed-98bf-4c2f-8dc5-78af595f6ad3
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/139885
dc.identifier.urihttps://doi.org/10.3113/fai.2009.0353
dc.description.abstractBackground: The use of external ring fixation for ankle arthrodesis offers an alternative to internal screw fixation when bone quality is suboptimal, when complex ankle pathology is present, and as a salvage procedure for complicated cases. Additionally, it permits earlier weightbearing and postoperative adjustment of bone alignment and joint compression. This study was designed to determine whether there are differences in initial ankle joint fixation integrity between these two techniques. Materials and Methods: Ten fresh-frozen cadaveric lower extremities underwent ankle arthrodesis with a hybrid ring fixator, and the bending and torsional stiffness of each arthrodesed joint was quantified. Stiffness was calculated from angulation measured at the tibiotalar joint using electronic clinometers attached to those bones. The external fixators were then removed and ankle arthrodesis performed using 6.5-mm cannulated screws: three across the ankle joint, one fixing the fibula to the tibia, and one fixing the fibula to the talus. Stiffness testing was then repeated. Results: No statistically significant difference in bending stiffness, torsional stiffness, or joint rotation under torsional load was demonstrable between the two techniques. Conclusion: The similarity in ankle fusion site stability achieved with external ring fixation and an optimized screw fixation technique under the described testing conditions indicates that, in cases in which suboptimal bone quality or complex ankle pathology preclude the use of internal fixation, an external fixator is a viable option. Clinical Relevance: Establishing that the primary stability of external ring fixation is comparable to that of screw fixation provides a basis for its use in cases in which screw fixation may be problematic.
dc.language.isoeng
dc.subjectSağlık Bilimleri
dc.subjectCerrahi Tıp Bilimleri
dc.subjectOrtopedi ve Travmatoloji
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectORTOPEDİ
dc.titleExternal Ring Fixation Versus Screw Fixation for Ankle Arthrodesis: A Biomechanical Comparison
dc.typeMakale
dc.relation.journalFOOT & ANKLE INTERNATIONAL
dc.contributor.department, ,
dc.identifier.volume30
dc.identifier.issue4
dc.identifier.startpage353
dc.identifier.endpage360
dc.contributor.firstauthorID192038


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster