dc.contributor.author | Teker, Aysenur Meric | |
dc.contributor.author | Ulug, Tuncay | |
dc.date.accessioned | 2021-03-05T20:45:19Z | |
dc.date.available | 2021-03-05T20:45:19Z | |
dc.date.issued | 2009 | |
dc.identifier.citation | Ulug T., Teker A. M. , "Minimally Invasive Cochlear Implantation with Mastoidal Three-Layer Flap Technique", ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, cilt.71, ss.292-298, 2009 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.other | av_d5b3b4d9-8fbc-4840-aa5b-27f53fbf81e1 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/141008 | |
dc.identifier.uri | https://doi.org/10.1159/000258680 | |
dc.description.abstract | Aims: To describe and evaluate a minimally invasive cochlear implantation approach using mastoidal three-layer flap (TLF) technique. Methods: We conducted a prospective clinical study at a tertiary referral center. The study population comprised 32 males and 16 females, with an age range of 1-51 years. Thirty-nine patients were operated on using the TLF technique and 9 patients were operated on using a classical cochlear implantation technique. The TLF technique was based on using the superficial musculoaponeurotic system (SMAS) as an additional, strong flap layer. The TLF, with 3 different pedicules, comprised an anteriorly based 4-cm skin flap, a superiorly based temporomastoidal flap, which included the SMAS, and an anteriorly based periostal Palva type flap in the same mastoidal area. Results: No major complications, including flap-wound problems and receiver-stimulator migration or extrusion, were encountered. The mean operation time was 66 min in the TLF population and 92 min in the classical operation population, which shows a statistically significant difference noted in the time of operation (p = 0.0001). Conclusion: The TLF cochlear implantation enables complete receiver-stimulator coverage and safe fixation without any additional procedures, while allowing reduced operation time. Copyright (C) 2009 S. Karger AG, Basel | |
dc.language.iso | eng | |
dc.subject | Cerrahi Tıp Bilimleri | |
dc.subject | Kulak Burun Boğaz | |
dc.subject | Sağlık Bilimleri | |
dc.subject | Tıp | |
dc.subject | Klinik Tıp (MED) | |
dc.subject | Klinik Tıp | |
dc.subject | KULAK BURUN BOĞAZ | |
dc.title | Minimally Invasive Cochlear Implantation with Mastoidal Three-Layer Flap Technique | |
dc.type | Makale | |
dc.relation.journal | ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES | |
dc.contributor.department | Bezmiâlem Vakıf Üniversitesi , , | |
dc.identifier.volume | 71 | |
dc.identifier.issue | 5 | |
dc.identifier.startpage | 292 | |
dc.identifier.endpage | 298 | |
dc.contributor.firstauthorID | 135638 | |