Basit öğe kaydını göster

dc.contributor.authorNorden, Imke
dc.contributor.authorYurudu, Nazmiye Özlem
dc.contributor.authorTuretgen, Irfan
dc.date.accessioned2021-03-05T21:12:15Z
dc.date.available2021-03-05T21:12:15Z
dc.date.issued2012
dc.identifier.citationTuretgen I., Yurudu N. Ö. , Norden I., "Biofilm formation comparison of the SANIPACKING (R) cooling tower fill material against standard polypropylene fill material in a recirculating model water system", TURKISH JOURNAL OF BIOLOGY, cilt.36, ss.313-318, 2012
dc.identifier.issn1300-0152
dc.identifier.othervv_1032021
dc.identifier.otherav_d7c7074e-d70b-4b8d-935b-c10b271c9fcf
dc.identifier.urihttp://hdl.handle.net/20.500.12627/142370
dc.identifier.urihttps://doi.org/10.3906/biy-1103-5
dc.description.abstractCooling towers are heat rejection systems that are used in some industrial applications, and they have the potential to develop infectious concentrations of Legionella pneumophila. SANIPACKING (R) cooling tower fill material and standard polypropylene fill material were compared in terms of biofilm formation potential and anti-Legionella activity within a 4-month period using a laboratory-scale recirculating water system. The recirculating water system was experimentally infected with a L. pneumophila standard strain (ATCC 33152) suspension and operated continuously until all experiments had been completed. Results showed that the L. pneumophila rapidly multiplied in a short time during the study within the model system bulk water. No L. pneumophila was isolated from the SANIPACKING (R) surface during the 4-month period, whereas intensive colonization occurred on the standard polypropylene material surface in the first month. Heterotrophic bacterial counts on the surfaces showed that a significantly low accumulation was recorded on the SANIPACKING (R) surface in comparison to the standard polypropylene material. Total bacterial counts on surfaces, determined by epifluorescence microscopy (using DAPI), revealed that significantly low counts of microorganisms colonized on the SANIPACKING (R) surface.
dc.language.isoeng
dc.subjectYaşam Bilimleri
dc.subjectTemel Bilimler
dc.subjectTemel Tıp Bilimleri
dc.subjectTıbbi Biyoloji
dc.subjectBiyokimya
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectBiyoloji ve Biyokimya
dc.subjectBİYOLOJİ
dc.titleBiofilm formation comparison of the SANIPACKING (R) cooling tower fill material against standard polypropylene fill material in a recirculating model water system
dc.typeMakale
dc.relation.journalTURKISH JOURNAL OF BIOLOGY
dc.contributor.departmentGEA 2H Water Technol GmbH , ,
dc.identifier.volume36
dc.identifier.issue3
dc.identifier.startpage313
dc.identifier.endpage318
dc.contributor.firstauthorID68552


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster