Show simple item record

dc.contributor.authorBaslo, Mehmet Barış
dc.contributor.authorOge, Ali Emre
dc.contributor.authorSirin, N. Gorkem
dc.contributor.authorGoker, Imran
dc.date.accessioned2021-03-02T22:30:22Z
dc.date.available2021-03-02T22:30:22Z
dc.identifier.citationGoker I., Baslo M. B. , Sirin N. G. , Oge A. E. , "Development of a Method to Analyze Compound Action Potential (CMAP) Scan Used in the Diagnosis and Monitoring of Neuromuscular Diseases", Medical Technologies National Congress (TIPTEKNO), Magusa, CYPRUS, 8 - 10 Kasım 2018
dc.identifier.othervv_1032021
dc.identifier.otherav_0d11e4c7-f770-4f1a-9203-d687dc5f993e
dc.identifier.urihttp://hdl.handle.net/20.500.12627/14405
dc.identifier.urihttps://doi.org/10.1109/tiptekno.2018.8597153
dc.description.abstractMotor Unit Number Estimate (MUNE) is a quantitative method which has been developed to determine the axon number as close as possible to the real axon number. It is used to assess and to monitor neuromuscular diseases such as anterior horn diseases. The Electrophysiological muscle scan is based on recording Compound Muscle Action Potentials (CMAPs) as response of the muscles innervated by the nerves being stimulated by gradually increased electrical currents. The purpose of this study is to develop a method which will ensure the MUNE by the analysis of the data obtained via electrohysiological muscle scan. CMAPs which were generetaed as a result of gradual stimulation in simulator software were recorded. The absolute values of the differences of CMAPs and the ratio of the mean of these values to the maximum CMAP value were computed through a software created in MATLAB to calculate MUNE values. Hence, it was intended to determine the relationship between the real axon count and MUNE.
dc.language.isoeng
dc.subjectTIBBİ LABORATUVAR TEKNOLOJİSİ
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectTemel Tıp Bilimleri
dc.subjectBiyoistatistik ve Tıp Bilişimi
dc.subjectBiyomedikal Mühendisliği
dc.subjectMühendislik ve Teknoloji
dc.subjectGeneral Engineering
dc.subjectEngineering (miscellaneous)
dc.subjectBiomedical Engineering
dc.subjectBioengineering
dc.subjectKlinik Tıp
dc.subjectHealth Informatics
dc.subjectPhysical Sciences
dc.subjectHealth Sciences
dc.subjectMedical Laboratory Technology
dc.subjectKlinik Tıp (MED)
dc.subjectTIBBİ BİLİŞİM
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, BİYOMEDİKSEL
dc.titleDevelopment of a Method to Analyze Compound Action Potential (CMAP) Scan Used in the Diagnosis and Monitoring of Neuromuscular Diseases
dc.typeBildiri
dc.contributor.departmentİstanbul Arel Üniversitesi , ,
dc.contributor.firstauthorID2274616


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record