Basit öğe kaydını göster

dc.contributor.authorBilmenoglu, Caglar
dc.contributor.authorGeckili, Onur
dc.contributor.authorBilhan, Hakan
dc.contributor.authorErdogan, Ozge
dc.contributor.authorCilingir, Altug
dc.contributor.authorKesoglu, Aysun Coskun
dc.contributor.authorOzdiler, Arda
dc.date.accessioned2021-03-06T07:25:06Z
dc.date.available2021-03-06T07:25:06Z
dc.date.issued2015
dc.identifier.citationGeckili O., Cilingir A., Erdogan O., Kesoglu A. C. , Bilmenoglu C., Ozdiler A., Bilhan H., "The Influence of Momentary Retention Forces on Patient Satisfaction and Quality of Life of Two-Implant-Retained Mandibular Overdenture Wearers", INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, cilt.30, ss.397-402, 2015
dc.identifier.issn0882-2786
dc.identifier.othervv_1032021
dc.identifier.otherav_dc74ed45-ee32-409b-a55a-7bec0ffe9b24
dc.identifier.urihttp://hdl.handle.net/20.500.12627/145292
dc.identifier.urihttps://doi.org/10.11607/jomi.3774
dc.description.abstractPurpose: The purpose of this study was to assess the influence of momentary retention forces on patient satisfaction and quality of life of two-implant-retained mandibular overdenture wearers. Materials and Methods: Edentulous patients who had been rehabilitated with two-implant-supported mandibular overdentures with single attachments and maxillary complete dentures at a university clinic were included in this study. The overdenture attachments were either ball or locator attachments. All the patients completed the Turkish version of the Oral Health Impact Profile-14 (OHIP-14) and the visual analog scale (VAS) satisfaction questionnaires. Momentary retention forces of the overdentures were measured using a custom-made dynamic testing machine. Results: Fifty-five patients were included in this study. No statistically significant association was detected between momentary retention forces and VAS scores (P > .05), but higher retention forces presented significantly better quality of life scores in the social disability and handicap domains of OHIP14 (P < .05). Conclusion: Within the limitations of this clinical study, it may be presumed that although higher instant retention force of an implant-retained overdenture provides better quality of life, it does not affect patient satisfaction.
dc.language.isoeng
dc.subjectKlinik Tıp (MED)
dc.subjectSağlık Bilimleri
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.subjectKlinik Tıp
dc.subjectTıp
dc.subjectDiş Hekimliği
dc.titleThe Influence of Momentary Retention Forces on Patient Satisfaction and Quality of Life of Two-Implant-Retained Mandibular Overdenture Wearers
dc.typeMakale
dc.relation.journalINTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS
dc.contributor.departmentİstanbul Okan Üniversitesi , ,
dc.identifier.volume30
dc.identifier.issue2
dc.identifier.startpage397
dc.identifier.endpage402
dc.contributor.firstauthorID73188


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster