Basit öğe kaydını göster

dc.contributor.authorDemir, B
dc.contributor.authorGunhan, B
dc.contributor.authorKoca, A
dc.contributor.authorEmre, D
dc.contributor.authorAkin, N
dc.contributor.authorKaracam, S
dc.date.accessioned2021-03-06T07:31:38Z
dc.date.available2021-03-06T07:31:38Z
dc.date.issued2005
dc.identifier.citationGunhan B., Karacam S., Koca A., Demir B., Emre D., Akin N., "Depth dose characteristics of electron beams at extended SSDS", PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, cilt.21, ss.75-80, 2005
dc.identifier.issn1120-1797
dc.identifier.othervv_1032021
dc.identifier.otherav_dcb86e6c-1430-4bb9-9c6f-d6aea66303eb
dc.identifier.urihttp://hdl.handle.net/20.500.12627/145461
dc.identifier.urihttps://doi.org/10.1016/s1120-1797(05)80023-7
dc.description.abstractThe purpose of this study is to investigate the behaviour of the percent depth dose curves (%DD) and surface doses of electron beams at extended Source-to Surface Distances (SSDS). A GE Saturne 42 linear accelerator was used in this study, which produces dual photon energies of 6 and 15 MW as well as eight electron energies ranging between 4.5 and 21 MeV The % Depth Dose curves were generated with water scanning equipment at 6, 9, and 15 MeV for 4 x 4 cm(2) and 20 x 20 cm(2) field sizes at SSDS of 100 cm, 108 cm, and 115 cm. According to the measurements from surface to the depth of dose maximum the surface dose increased for all of the electron energies studied at extended SSDS for small field sizes. On the other hand for larger field sizes the surface doses decreased at extended SSDS. It was also observed that the increase in the surface dose diminished as the field size approached to 10 x 10cm(2) then the surface dose started decreasing at extended SSDS as the field sizes increased. Extended SSDs have no observable effect on the tail portion of the depth dose curves.
dc.language.isoeng
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectDahili Tıp Bilimleri
dc.subjectNükleer Tıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectRADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME
dc.titleDepth dose characteristics of electron beams at extended SSDS
dc.typeMakale
dc.relation.journalPHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS
dc.contributor.department, ,
dc.identifier.volume21
dc.identifier.issue2
dc.identifier.startpage75
dc.identifier.endpage80
dc.contributor.firstauthorID85532


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster