Basit öğe kaydını göster

dc.contributor.authorBarles, Hulusi
dc.contributor.authorArayici, Semiha
dc.contributor.authorGonder, Z. Beril
dc.date.accessioned2021-03-06T08:00:19Z
dc.date.available2021-03-06T08:00:19Z
dc.date.issued2011
dc.identifier.citationGonder Z. B. , Arayici S., Barles H., "Advanced treatment of pulp and paper mill wastewater by nanofiltration process: Effects of operating conditions on membrane fouling", SEPARATION AND PURIFICATION TECHNOLOGY, cilt.76, ss.292-302, 2011
dc.identifier.issn1383-5866
dc.identifier.otherav_dee834dc-8de3-4f08-b3d9-03d7a546c765
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/146848
dc.identifier.urihttps://doi.org/10.1016/j.seppur.2010.10.018
dc.description.abstractIn this study, the application of two-step nanofiltration (NF) process was investigated in the purification of biologically treated pulp and paper wastewater for the purpose of reuse. In the first step, the effect of operating conditions such as pH, temperature, transmembrane pressure and volume reduction factor (VRF) on the membrane fouling was investigated using FM NP010 membrane. Membrane fouling was minimized by optimizing the operating conditions using Taguchi experimental design method. The smaller-the-better signal-to-noise (S/N) ratio was used to analyze the results of experiments. Flux decline caused by fouling was selected as response parameter. The best results were obtained at third level of pH (10), first level of temperature (25 degrees C), first level of transmembrane pressure (12 bar) and third level of VRF (4) which provided minimum flux decline caused by fouling (11%). Based on the analysis of variance (ANOVA), the results indicated that transmembrane pressure has significant effect on membrane fouling, while VRF shows very little effect on membrane fouling. Membrane fouling was further examined in terms of atomic force microscopy (AFM) and scanning electron microscopy (SEM) analysis. Under the optimized conditions, 91% chemical oxygen demand (COD), 92% total hardness and 98% sulphate removal were achieved using FM NP010 membrane. Also the obtained permeate is colorless and free from suspended solids. However, chloride and conductivity were partially removed. In the second step, FM NP030 membrane was used to provide better permeate quality like actual process water. Membrane fouling was also investigated in terms of flux decline, contact angle measurements and SEM analysis in this step. As a conclusion, the water produced by two step NF treatment of biologically treated pulp and paper industry meets the quality of actual process water. (c) 2010 Elsevier B.V. All rights reserved.
dc.language.isoeng
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik ve Teknoloji
dc.subjectMÜHENDİSLİK, KİMYASAL
dc.subjectMühendislik
dc.subjectKimya Mühendisliği ve Teknolojisi
dc.titleAdvanced treatment of pulp and paper mill wastewater by nanofiltration process: Effects of operating conditions on membrane fouling
dc.typeMakale
dc.relation.journalSEPARATION AND PURIFICATION TECHNOLOGY
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume76
dc.identifier.issue3
dc.identifier.startpage292
dc.identifier.endpage302
dc.contributor.firstauthorID198748


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster