dc.date.issued2015
dc.identifier.citationCansiz E., Dogru S. C. , Arslan Y. Z. , "COMPARATIVE EVALUATION OF THE MECHANICAL PROPERTIES OF RESORBABLE AND TITANIUM MINIPLATES USED FOR FIXATION OF MANDIBULAR CONDYLE FRACTURES", JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, cilt.15, sa.2, 2015
dc.identifier.issn0219-5194
dc.identifier.otherav_1081d8e5-a594-4574-ba72-56598ae40386
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/16594
dc.identifier.urihttps://doi.org/10.1142/s0219519415400321
dc.description.abstractIn this paper, comparative evaluation of the mechanical properties of resorbable and titanium miniplates, which are used for the fixation of the mandibular condyle fractures, was carried out using finite element analysis (FEA). To do so, first two-dimensional (2D) computed tomography (CT) images of mandibles recorded from 10 adult patients were converted into three-dimensional (3D) solid body models. Then these models were transferred to the finite element software. In the finite element stage of the study, a condyle fracture was created onto the mandible and double-titanium and double-resorbable miniplates were separately fixed to the mandible surface such that the fractured sites to be firmly attached. Stress distribution over the plates and interfragmentary displacements between adjacent surfaces, which stem from the clenching force applying to the mandible, were calculated using FEA. It was observed from the results that maximum tensile stresses occurred in the titanium miniplates were significantly higher than those obtained from resorbable miniplates (p < 0.01). Higher maximum displacements between fractured surfaces were observed in the case of resorbable plate systems (p < 0.01). Maximum stress and displacement values obtained from both titanium and resorbable plate systems were under clinically acceptable limits. According to results, resorbable plates showed a similar reliability with titanium miniplates in terms of withstanding various stress and strain deformations.
dc.language.isoeng
dc.subjectSağlık Bilimleri
dc.subjectTemel Tıp Bilimleri
dc.subjectBiyofizik
dc.subjectBiyokimya
dc.subjectBiyomedikal Mühendisliği
dc.subjectYaşam Bilimleri
dc.subjectTemel Bilimler
dc.subjectMühendislik ve Teknoloji
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectTıp
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, BİYOMEDİKSEL
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectBiyoloji ve Biyokimya
dc.subjectBİYOFİZİK
dc.titleCOMPARATIVE EVALUATION OF THE MECHANICAL PROPERTIES OF RESORBABLE AND TITANIUM MINIPLATES USED FOR FIXATION OF MANDIBULAR CONDYLE FRACTURES
dc.typeMakale
dc.relation.journalJOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume15
dc.identifier.issue2
dc.contributor.firstauthorID80913


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster