Basit öğe kaydını göster

dc.contributor.authorYenier, Gülşah
dc.contributor.authorTarım, Berna
dc.date.accessioned2021-12-10T10:35:38Z
dc.date.available2021-12-10T10:35:38Z
dc.identifier.citationYenier G., Tarım B., "Evaluation of adhesive interface degradation on bond strength with different adhesive applications.", AIC 19th International Congress and Conseuro, Bologna, İtalya, 11 - 13 Mayıs 2017, cilt.21, ss.1359-1433
dc.identifier.othervv_1032021
dc.identifier.otherav_491fea91-0c23-4509-88da-df330cbb2d90
dc.identifier.urihttp://hdl.handle.net/20.500.12627/170208
dc.identifier.urihttps://link.springer.com/content/pdf/10.1007%2Fs00784-017-2109-z.pdf
dc.description.abstractEVALUATION OF ADHESIVE INTERFACE DEGRADATION ON BOND STRENGTH WITH DIFFERENT ADHESIVE APPLICATIONSThe purpose of this study was to evaluate the influence of 2% Chlorhexidine (CHX), double adhesive layer (DA), extra hybrophobic resin layer (HL) applications proposed to decrease adhesive interface degradation on the microtensile dentin bond strength of simplified adhe- sive systems.Two-step etch&rinse system Adper Single Bond2 [SB] and one-step self- etch system Clearfil S3 Bond [S3] were tested, two-step self-etch adhe- sive system Clearfil SE Bond [SE] was used as control. Seventy-two extracted human third molars dentin occlusal surfaces were exposed by grinding with 600-grit SiC paper. The adhesives were applied according to the manufacturer’s directions [MD], or with 2% Chlorhexidine [CHX] application or double application of the adhesive layer [DA] or following the manufacturer’s directions extra hydrophobic resin layer coating [HL]. After applying the adhesive resins, composite crowns were built up in- crementally. After 24-h water storage, the specimens were serially sec- tioned in“x”and“y”directions to obtain bonded sticks of about 1.0 mm2 to be tested immediately [IM] or after 6 months of water storage [6M] at a crosshead speed of 0.5 mm/min. The data from each adhesive was ana- lyzed by Three-way ANOVA (adhesive system, mode of application vs. storage time) and Tukey’s test (p = 0.05).After 6-months, all adhesives bond strength reduced significantly (p<0.01). SE showed the highest bond strength while no difference was found between SB-MD and S3-MD (p>0,05). Higher bond strengths values were observed for CHX, DA and HL applications, however HL and DA were significantly different from the manufacturer’s directions (p<0.01) and HL bond strength was the highest (p<0.01). When com- pared the adhesive systems only DA and HL application for S3 was significantly higher (p<0.01).The application of DA and HL can improve the resin-dentin bonds and decrease the adhesive interface degradation.
dc.language.isoeng
dc.subjectKlinik Tıp (MED)
dc.subjectSağlık Bilimleri
dc.titleEvaluation of adhesive interface degradation on bond strength with different adhesive applications.
dc.typeBildiri
dc.contributor.departmentİstanbul Üniversitesi , Diş Hekimliği Fakültesi , Klinik Bilimler Bölümü
dc.identifier.volume21
dc.contributor.firstauthorID2696876


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster