Basit öğe kaydını göster

dc.contributor.authorGuler, Elif
dc.contributor.authorALHAN, Cenk
dc.date.accessioned2021-12-10T10:50:50Z
dc.date.available2021-12-10T10:50:50Z
dc.identifier.citationGuler E., ALHAN C., "Performance limits of base-isolated liquid storage tanks with/without supplemental dampers under near-fault earthquakes", STRUCTURES, cilt.33, ss.355-367, 2021
dc.identifier.issn2352-0124
dc.identifier.othervv_1032021
dc.identifier.otherav_57d4ea22-b346-481f-b383-c6bf0c37f30b
dc.identifier.urihttp://hdl.handle.net/20.500.12627/170698
dc.identifier.urihttps://doi.org/10.1016/j.istruc.2021.04.023
dc.description.abstractIn order to ensure the continuity of the production process and avoid health, security, and ecological problems, the protection of the liquid storage tanks (LSTs) in industrial complexes against earthquakes is vital. Although base-isolation is successful in protecting LSTs from the detrimental effects of far-fault earthquakes, it is challenged by large-amplitude and long-period velocity pulses observed in near-fault earthquakes which may cause large isolator and sloshing displacements. Employing supplemental damping in the isolation system may reduce isolator displacements but the improvement in the superstructure response may be limited if not worsened. Thus, determining the performance limits of base-isolated LSTs with/without supplemental damping in terms of both isolation system and superstructure responses through a systematic examination considering different levels of earthquake magnitude and different fault distances is essential. Since the period and the amplitude of the ground velocity pulse is dependent on the earthquake magnitude and the closest fault distance, such an examination will also help reveal the influence of the characteristic properties of near-fault pulses on the responses of these structures. Therefore, here, a benchmark LST with different base-isolation systems with/without supplemental viscous dampers, located at different fault distances are subjected to synthetically generated near-fault earthquake records with different levels of moment magnitudes. Various isolator and viscous damper characteristics are taken into account. Non-linear time history analyses are conducted to obtain isolator displacement, sloshing displacement, and isolation system shear force responses and the performance limits of the benchmark LST with different base-isolation systems with/without supplemental dampers are presented in a comparative manner.
dc.language.isoeng
dc.subjectCivil and Structural Engineering
dc.subjectPhysical Sciences
dc.subjectGeneral Engineering
dc.subjectEngineering (miscellaneous)
dc.subjectMühendislik ve Teknoloji
dc.subjectİnşaat Mühendisliği
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, SİVİL
dc.titlePerformance limits of base-isolated liquid storage tanks with/without supplemental dampers under near-fault earthquakes
dc.typeMakale
dc.relation.journalSTRUCTURES
dc.contributor.departmentİstanbul Üniversitesi-Cerrahpaşa , ,
dc.identifier.volume33
dc.identifier.startpage355
dc.identifier.endpage367
dc.contributor.firstauthorID2742807


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster