Show simple item record

dc.contributor.authorBilen, Ahmet
dc.contributor.authorSezdi, Mana
dc.date.accessioned2021-03-02T23:17:48Z
dc.date.available2021-03-02T23:17:48Z
dc.date.issued2017
dc.identifier.citationSezdi M., Bilen A., "Dose and Time Controlled Electronic Insulin Pen: Bilensulin", ISTANBUL UNIVERSITY-JOURNAL OF ELECTRICAL AND ELECTRONICS ENGINEERING, cilt.17, sa.1, ss.3074-3079, 2017
dc.identifier.othervv_1032021
dc.identifier.otherav_119fb452-7d42-4a17-8d25-c76f3eb6adcc
dc.identifier.urihttp://hdl.handle.net/20.500.12627/17314
dc.description.abstractIn this study, an electronic insulin pen was designed for diabetic patients dependent on insulin use in order to prevent wrong timing and wrong dosage caused from old age, vision or mental illness. During design, the patients' necessities such as easy-to-use, have been considered. The insulin pen that can be used electronically for routine dose injections, and that is called as Bilensulin, was designed to be able to used manually in the emergency. It is aimed that the patient can set the dose easily by using the fairly simple menu of the device. Additionally, the device was designed as reusable by changing the insulin cartridge. Because the tube chamber was designed to be suitable for all types of insulin, it can be used by changing cartridge without using different pen. Dose accuracy was tested by performing insulin dose measurements on a sensitive balance, and dose of Bilensulin was compared with the three types of insulin pens. The patent has been applied for this designed electronic insulin pen. The mechanism of change of cartridge has been put into the foreground in terms of ease of use and constituted the sub-structure of the patent application. Currently, the studies on the device are continuing.
dc.language.isoeng
dc.subjectBiyolojik Oşinografi (Deniz Biyolojisi
dc.subjectBilgi Sistemleri, Haberleşme ve Kontrol Mühendisliği
dc.subjectSinyal İşleme
dc.subjectMühendislik ve Teknoloji
dc.subjectDeniz Bilimleri ve Teknolojisi
dc.subjectOşinografi
dc.subjectMÜHENDİSLİK, ELEKTRİK VE ELEKTRONİK
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, OCEAN
dc.titleDose and Time Controlled Electronic Insulin Pen: Bilensulin
dc.typeMakale
dc.relation.journalISTANBUL UNIVERSITY-JOURNAL OF ELECTRICAL AND ELECTRONICS ENGINEERING
dc.contributor.departmentİstanbul Yeni Yüzyıl Üniversitesi , ,
dc.identifier.volume17
dc.identifier.issue1
dc.identifier.startpage3074
dc.identifier.endpage3079
dc.contributor.firstauthorID238683


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record