Show simple item record

dc.contributor.authorGÜNGÖR, Zeynep Banu
dc.contributor.authorDicle, Diclehan Ali
dc.contributor.authorÖZYÜREK, Mustafa
dc.contributor.authorKUCUR, Mine
dc.contributor.authorKamis, Handan
dc.contributor.authorFilik, Hayati
dc.contributor.authorAVAN, Asiye Aslıhan
dc.contributor.authorALTAŞ PUNTAR, Nilay
dc.date.accessioned2021-12-10T13:19:21Z
dc.date.available2021-12-10T13:19:21Z
dc.identifier.citationFilik H., AVAN A. A. , ALTAŞ PUNTAR N., ÖZYÜREK M., GÜNGÖR Z. B. , KUCUR M., Kamis H., Dicle D. A. , "Ethylenediamine grafted carbon nanotube aerogels modified screen-printed electrode for simultaneous electrochemical immunoassay of multiple tumor markers", JOURNAL OF ELECTROANALYTICAL CHEMISTRY, cilt.900, 2021
dc.identifier.issn1572-6657
dc.identifier.othervv_1032021
dc.identifier.otherav_fed0847c-d2ae-4606-b9a6-9efeafe0d3c8
dc.identifier.urihttp://hdl.handle.net/20.500.12627/175931
dc.identifier.urihttps://doi.org/10.1016/j.jelechem.2021.115700
dc.description.abstractA sensitive sandwich-model immunoassay designed for simultaneous electrochemical measurement of alphafetoprotein and carcinoembryonic antigen handling multiple-label strategy. The sandwich-model immunosensor was constructed by assembling ethylenediamine-MWCNT aerogels (EDA-CAGs), AuNPs and capture antibodies (Cp-Ab1) on the screen-printed carbon electrode (SPCE). The prepared EDA-CAG textures were analyzed using Fourier transform infrared (FT-IR), Scanning Electron Microscopy (SEM) and Energy Dispersive X-Ray Spectroscopy (EDX). In this protocol, AuNPs decorated EDA-CAG-carried Thionine (Thi) and AuNPs decorated EDA-CAG-carried Safranine O (SfO) (denoted as AuNP-Thi-EDA-CAG and AuNP-SfOEDA-CAG, respectively) were properly exploited as distinguishable signal labels, which were used to attach detection antibodies (Ab2) (anti-AFP2 and anti-CEA2), respectively. When two tumor antigens were present, a square wave voltammetry (SWV) scan displayed two well-separated signals, each signal indicated one target antigen. Observed results introduced that the square wave voltammetric peak current exhibited a good linear relationship to logarithm concentration in the ranges from 0.005 to 1.0 ng/mL for both analytes. The LoDs were 0.0015 and 0.0010 ng/mL (at signal/noise S/N = 3) for AFP and CEA, respectively. The designed sandwich-type immunosensor was applied to real serum sample analysis.
dc.language.isoeng
dc.subjectTemel Bilimler
dc.subjectAnalytical Chemistry
dc.subjectFiltration and Separation
dc.subjectElectrochemistry
dc.subjectChemistry (miscellaneous)
dc.subjectGeneral Chemistry
dc.subjectPhysical Sciences
dc.subjectFizikokimya
dc.subjectElektrokimya
dc.subjectAnalitik Kimya
dc.subjectELEKTROKİMYA
dc.subjectTemel Bilimler (SCI)
dc.subjectKimya
dc.subjectKİMYA, ANALİTİK
dc.titleEthylenediamine grafted carbon nanotube aerogels modified screen-printed electrode for simultaneous electrochemical immunoassay of multiple tumor markers
dc.typeMakale
dc.relation.journalJOURNAL OF ELECTROANALYTICAL CHEMISTRY
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume900
dc.contributor.firstauthorID2750458


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record