Basit öğe kaydını göster

dc.contributor.authorPalacios Hernandez, Elvia Ruth
dc.contributor.authorMendez, Martin O.
dc.contributor.authorKortelainen, Juha M.
dc.contributor.authorTenhunen, Mirja
dc.contributor.authorBianchi, Anna Maria
dc.contributor.authorGuerrero Mora, Guillermina
dc.date.accessioned2022-02-18T09:24:35Z
dc.date.available2022-02-18T09:24:35Z
dc.date.issued2015
dc.identifier.citationGuerrero Mora G., Kortelainen J. M. , Palacios Hernandez E. R. , Tenhunen M., Bianchi A. M. , Mendez M. O. , "Evaluation of Pressure Bed Sensor for Automatic SAHS Screening", IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, cilt.64, sa.7, ss.1935-1943, 2015
dc.identifier.issn0018-9456
dc.identifier.othervv_1032021
dc.identifier.otherav_3867111d-1121-4b82-8822-48b2f06455c9
dc.identifier.urihttp://hdl.handle.net/20.500.12627/177155
dc.identifier.urihttps://doi.org/10.1109/tim.2014.2366976
dc.description.abstractWe evaluate the performance of an unobtrusive sleep monitoring system in the detection of the sleep apnea-hypopnea syndrome (SAHS). The proposed system is a pressure bed sensor (PBS) that incorporates multiple pressure sensors into a bed mattress to measure several physiological signals of the sleeping subject: respiration; heart rate; and body movements. An automatic algorithm is developed to calculate a respiratory event index (REI). The recordings of 24 patients with suspected sleep problems are analyzed, and the results are compared with the gold standard methods; first with manual scoring of polysomnography to calculate the apnea-hypopnea index (AHI), and second with automatic detection of REI from the respiratory inductive plethysmography belts. The correlation coefficient between AHI and REI from PBS is up to 0.93. Evaluating the ability of PBS in the diagnosis of pathologic (AHI = 5) and nonpathologic (AHI < 5) subjects, we obtained a sensitivity, specificity, and accuracy of 100%, 92%, and 96%, respectively. To diagnose three levels of SAHS, mild, moderate, and severe, the Cohen's kappa value is 0.76. These findings support that PBS recording could provide a simple and unobtrusive method for detection of SAHS in home monitoring.
dc.language.isoeng
dc.subjectGeneral Engineering
dc.subjectEngineering (miscellaneous)
dc.subjectElectrical and Electronic Engineering
dc.subjectInstrumentation
dc.subjectPhysical Sciences
dc.subjectSinyal İşleme
dc.subjectMühendislik ve Teknoloji
dc.subjectSignal Processing
dc.subjectBilgi Sistemleri, Haberleşme ve Kontrol Mühendisliği
dc.subjectALETLER & GÖSTERİM
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, ELEKTRİK VE ELEKTRONİK
dc.titleEvaluation of Pressure Bed Sensor for Automatic SAHS Screening
dc.typeMakale
dc.relation.journalIEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT
dc.contributor.departmentUniversidad Autónoma De San Luis Potosí , ,
dc.identifier.volume64
dc.identifier.issue7
dc.identifier.startpage1935
dc.identifier.endpage1943
dc.contributor.firstauthorID3383375


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster