Basit öğe kaydını göster

dc.contributor.authorLandsman, W.
dc.contributor.authorPage, M. J.
dc.contributor.authorYershov, V.
dc.contributor.authorBrown, P. J.
dc.contributor.authorCarter, M.
dc.contributor.authorMason, K. O.
dc.contributor.authorKennedy, T.
dc.contributor.authorMarshall, F.
dc.contributor.authorRoming, P. W. A.
dc.contributor.authorSiegel, M.
dc.contributor.authorOates, S.
dc.contributor.authorSmith, P. J.
dc.contributor.authorDE PASQUALE, Massımılıano
dc.contributor.authorKuin, N. P. M.
dc.contributor.authorBreeveld, A. A.
dc.contributor.authorLamoureux, H.
dc.contributor.authorJames, C.
dc.contributor.authorMehdipour, M.
dc.contributor.authorStill, M.
dc.date.accessioned2022-02-18T10:04:23Z
dc.date.available2022-02-18T10:04:23Z
dc.date.issued2015
dc.identifier.citationKuin N. P. M. , Landsman W., Breeveld A. A. , Page M. J. , Lamoureux H., James C., Mehdipour M., Still M., Yershov V., Brown P. J. , et al., "Calibration of the Swift-UVOT ultraviolet and visible grisms", MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, cilt.449, sa.3, ss.2514-2538, 2015
dc.identifier.issn0035-8711
dc.identifier.othervv_1032021
dc.identifier.otherav_7924ab3d-bd29-49e2-9eb7-01e09f1c8a80
dc.identifier.urihttp://hdl.handle.net/20.500.12627/178517
dc.identifier.urihttps://doi.org/10.1093/mnras/stv408
dc.description.abstractWe present the calibration of the Swift Ultraviolet and Optical Telescope (UVOT) grisms, of which there are two, providing low-resolution field spectroscopy in the ultraviolet and optical bands, respectively. The UV grism covers the range lambda 1700-5000 angstrom with a spectral resolution (lambda/Delta lambda) of 75 at lambda 2600 angstrom for source magnitudes of u= 10-16 mag, while the visible grism covers the range lambda 2850-6600 angstrom with a spectral resolution of 100 at lambda 4000 angstrom for source magnitudes of b=12-17 mag. This calibration extends over all detector positions, for all modes used during operations. The wavelength accuracy (1 sigma) is 9 angstrom in the UV grism clocked mode, 17 angstrom in the UV grism nominal mode and 22 angstrom in the visible grism. The range below lambda 2740 angstrom in the UV grism and lambda 5200 angstrom in the visible grism never suffers from overlapping by higher spectral orders. The flux calibration of the grisms includes a correction we developed for coincidence loss in the detector. The error in the coincidence loss correction is less than 20 per cent. The position of the spectrum on the detector only affects the effective area (sensitivity) by a fewper cent in the nominal modes, but varies substantially in the clocked modes. The error in the effective area is from 9 per cent in the UV grism clocked mode to 15 per cent in the visible grism clocked mode
dc.language.isoeng
dc.subjectGeneral Physics and Astronomy
dc.subjectASTRONOMİ VE ASTROFİZİK
dc.subjectUzay bilimi
dc.subjectTemel Bilimler (SCI)
dc.subjectFizik
dc.subjectAstronomi ve Astrofizik
dc.subjectTemel Bilimler
dc.subjectPhysics and Astronomy (miscellaneous)
dc.subjectAstronomy and Astrophysics
dc.subjectSpace and Planetary Science
dc.subjectPhysical Sciences
dc.titleCalibration of the Swift-UVOT ultraviolet and visible grisms
dc.typeMakale
dc.relation.journalMONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY
dc.contributor.departmentUniversity Of London , ,
dc.identifier.volume449
dc.identifier.issue3
dc.identifier.startpage2514
dc.identifier.endpage2538
dc.contributor.firstauthorID3383204


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster