Basit öğe kaydını göster

dc.contributor.authorBianchi, Anna M.
dc.contributor.authorRizzo, Giovanna
dc.contributor.authorTresoldi, Daniele
dc.contributor.authorArce-Santana, Edgar R.
dc.contributor.authorMendez, Martin O.
dc.contributor.authorMejia-Rodriguez, Aldo R.
dc.contributor.authorScalco, Elisa
dc.date.accessioned2022-02-18T10:34:48Z
dc.date.available2022-02-18T10:34:48Z
dc.identifier.citationMejia-Rodriguez A. R. , Scalco E., Tresoldi D., Bianchi A. M. , Arce-Santana E. R. , Mendez M. O. , Rizzo G., "A Mesh-Based Approach for the 3D Analysis of Anatomical Structures of Interest in Radiotherapy", 34th Annual International Conference of the IEEE Engineering-in-Medicine-and-Biology-Society (EMBS), California, Amerika Birleşik Devletleri, 28 Ağustos - 01 Eylül 2012, ss.6555-6558
dc.identifier.othervv_1032021
dc.identifier.otherav_a9483baa-19e9-46d0-b42e-a9bb5b654968
dc.identifier.urihttp://hdl.handle.net/20.500.12627/179500
dc.description.abstractIn this paper a method based on mesh surfaces approximations for the 3D analysis of anatomical structures in Radiotherapy (RT) is presented. Parotid glands meshes constructed from Megavoltage CT (MVCT) images were studied in terms of volume, distance between center of mass (distCOM) of the right and left parotids, dice similarity coefficient (DICE), maximum distance between meshes (DMax) and the average symmetric distance (ASD). A comparison with the standard binary images approach was performed. While absence of significant differences in terms of volume, DistCOM and DICE indices suggests that both approaches are comparable, the fact that the ASD showed significant difference (p=0.002) and the DMax was almost significant (p=0.053) suggests that the mesh approach should be adopted to provide accurate comparison between 3D anatomical structures of interest in RT.
dc.language.isoeng
dc.subjectSinyal İşleme
dc.subjectBiyomedikal Mühendisliği
dc.subjectMühendislik ve Teknoloji
dc.subjectSignal Processing
dc.subjectGeneral Engineering
dc.subjectEngineering (miscellaneous)
dc.subjectBiomedical Engineering
dc.subjectElectrical and Electronic Engineering
dc.subjectMÜHENDİSLİK, ELEKTRİK VE ELEKTRONİK
dc.subjectPhysical Sciences
dc.subjectBioengineering
dc.subjectBilgi Sistemleri, Haberleşme ve Kontrol Mühendisliği
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.subjectMühendislik
dc.subjectMÜHENDİSLİK, BİYOMEDİKSEL
dc.titleA Mesh-Based Approach for the 3D Analysis of Anatomical Structures of Interest in Radiotherapy
dc.typeBildiri
dc.contributor.departmentCNR , ,
dc.contributor.firstauthorID3379571


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster