Basit öğe kaydını göster

dc.contributor.authorOzkaya, Ufuk
dc.contributor.authorKabukcuoglu, Yavuz
dc.contributor.authorBilgili, Fuat
dc.contributor.authorBasilgan, Seckin
dc.contributor.authorParmaksizoglu, Atilla Sancar
dc.date.accessioned2022-02-18T10:38:09Z
dc.date.available2022-02-18T10:38:09Z
dc.date.issued2009
dc.identifier.citationParmaksizoglu A. S. , Ozkaya U., Bilgili F., Basilgan S., Kabukcuoglu Y., "Large diameter metal-on-metal total hip arthroplasty for Crowe IV developmental dysplasia of the hip", HIP INTERNATIONAL, cilt.19, sa.4, ss.309-314, 2009
dc.identifier.issn1120-7000
dc.identifier.otherav_adf81b2f-5c95-48f4-936b-de7b87509512
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/179599
dc.identifier.urihttps://doi.org/10.1177/112070000901900403
dc.description.abstractThe short-term results of middle-aged patients with severe developmental dysplasia of the hip treated with subtrochanteric femoral shortening and cementless large diameter metal-on-metal total hip arthroplasty were retrospectively evaluated. Clinical and radiological results of 15 hips of 13 patients with Crowe IV developmental dysplasia of the hip were enrolled in this study. The average follow-up period was 49 months (36-62 months). The average age of patients at the time of surgery was 45.5 years (range, 36-65 years). Radiographs were evaluated for component position, subsidence, loosening, and osteolysis. Intraoperatively, two patients had a small proximal femoral shaft split that was held with a cable wire. The average preoperative Harris hip score was 58; at 3 years, 82. Trendelenburg sign was negative in 11 hips at the last assessment. Loosening, subsidence, infection, dislocation, hypersensitivity and neurovascular complications were not observed. One hip had to be revised 1 year after surgery because of nonunion at the osteotomy site. Our study shows that large diameter metal-on-metal total hip arthroplasty, incorporating subtrochanteric femoral shortening, decreases dislocation rate and provides excellent results for the completely dislocated hip. (Hip International 2009; 19: 309-14)
dc.language.isoeng
dc.subjectPodiatry
dc.subjectHealth Sciences
dc.subjectCerrahi Tıp Bilimleri
dc.subjectOrthopedics and Sports Medicine
dc.subjectOrtopedi ve Travmatoloji
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectORTOPEDİ
dc.titleLarge diameter metal-on-metal total hip arthroplasty for Crowe IV developmental dysplasia of the hip
dc.typeMakale
dc.relation.journalHIP INTERNATIONAL
dc.contributor.departmentTaksim Training & Res Hosp , ,
dc.identifier.volume19
dc.identifier.issue4
dc.identifier.startpage309
dc.identifier.endpage314
dc.contributor.firstauthorID3215078


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster