Basit öğe kaydını göster

dc.contributor.authorYershov, V.
dc.contributor.authorCurran, P. A.
dc.contributor.authorHoversten, E. A.
dc.contributor.authorKoch, S.
dc.contributor.authorLandsman, W.
dc.contributor.authorMarshall, F. E.
dc.contributor.authorPage, M. J.
dc.contributor.authorPoole, T. S.
dc.contributor.authorRoming, P.
dc.contributor.authorSmith, P. J.
dc.contributor.authorStill, M.
dc.contributor.authorBlustin, A. J.
dc.contributor.authorBrown, P. J.
dc.contributor.authorGronwall, C.
dc.contributor.authorHolland, S. T.
dc.contributor.authorKuin, N. P. M.
dc.contributor.authorMcGowan, K.
dc.contributor.authorRosen, S.
dc.contributor.authorBoyd, P.
dc.contributor.authorBroos, P.
dc.contributor.authorCarter, M.
dc.contributor.authorChester, M. M.
dc.contributor.authorHancock, B.
dc.contributor.authorHuckle, H.
dc.contributor.authorImmler, S.
dc.contributor.authorIvanushkina, M.
dc.contributor.authorKennedy, T.
dc.contributor.authorMason, K. O.
dc.contributor.authorMorgan, A. N.
dc.contributor.authorOates, S.
dc.contributor.authorDE PASQUALE, Massımılıano
dc.contributor.authorSchady, P.
dc.contributor.authorSiegel, M.
dc.contributor.authorBerk, D. Vanden
dc.contributor.authorBreeveld, A. A.
dc.date.accessioned2022-02-18T10:48:35Z
dc.date.available2022-02-18T10:48:35Z
dc.date.issued2010
dc.identifier.citationBreeveld A. A. , Curran P. A. , Hoversten E. A. , Koch S., Landsman W., Marshall F. E. , Page M. J. , Poole T. S. , Roming P., Smith P. J. , et al., "Further calibration of the Swift ultraviolet/optical telescope", MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, cilt.406, sa.3, ss.1687-1700, 2010
dc.identifier.issn0035-8711
dc.identifier.othervv_1032021
dc.identifier.otherav_bd8b6d8f-51e0-40ba-9d4a-10b671fccaa4
dc.identifier.urihttp://hdl.handle.net/20.500.12627/179939
dc.identifier.urihttps://doi.org/10.1111/j.1365-2966.2010.16832.x
dc.description.abstractThe Ultraviolet/Optical Telescope (UVOT) is one of three instruments onboard the Swift observatory. The photometric calibration has been published, and this paper follows up with details on other aspects of the calibration including a measurement of the point spread function with an assessment of the orbital variation and the effect on photometry. A correction for large-scale variations in sensitivity over the field of view is described, as well as a model of the coincidence loss which is used to assess the coincidence correction in extended regions. We have provided a correction for the detector distortion and measured the resulting internal astrometric accuracy of the UVOT, also giving the absolute accuracy with respect to the International Celestial Reference System. We have compiled statistics on the background count rates, and discuss the sources of the background, including instrumental scattered light. In each case, we describe any impact on UVOT measurements, whether any correction is applied in the standard pipeline data processing or whether further steps are recommended.
dc.language.isoeng
dc.subjectTemel Bilimler
dc.subjectASTRONOMİ VE ASTROFİZİK
dc.subjectUzay bilimi
dc.subjectTemel Bilimler (SCI)
dc.subjectFizik
dc.subjectAstronomi ve Astrofizik
dc.subjectPhysics and Astronomy (miscellaneous)
dc.subjectGeneral Physics and Astronomy
dc.subjectSpace and Planetary Science
dc.subjectAstronomy and Astrophysics
dc.subjectPhysical Sciences
dc.titleFurther calibration of the Swift ultraviolet/optical telescope
dc.typeMakale
dc.relation.journalMONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY
dc.contributor.departmentUniversity Of London , ,
dc.identifier.volume406
dc.identifier.issue3
dc.identifier.startpage1687
dc.identifier.endpage1700
dc.contributor.firstauthorID3378067


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster