Basit öğe kaydını göster

dc.contributor.authorKapudan, Timucin
dc.contributor.authorCan, Ziya
dc.contributor.authorEren, Sule
dc.contributor.authorUzer, Aysem
dc.contributor.authorErcag, Erol
dc.contributor.authorApak, Resat
dc.date.accessioned2021-03-03T07:36:08Z
dc.date.available2021-03-03T07:36:08Z
dc.date.issued2010
dc.identifier.citationEren S., Uzer A., Can Z., Kapudan T., Ercag E., Apak R., "Determination of peroxide-based explosives with copper(II)-neocuproine assay combined with a molecular spectroscopic sensor", ANALYST, cilt.135, sa.8, ss.2085-2091, 2010
dc.identifier.issn0003-2654
dc.identifier.othervv_1032021
dc.identifier.otherav_12d5d903-2c71-4f87-92f8-26bef1e34ff0
dc.identifier.urihttp://hdl.handle.net/20.500.12627/18111
dc.identifier.urihttps://doi.org/10.1039/b925653a
dc.description.abstractThe two members of peroxide-based explosives, triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD), can be manufactured from readily accessible reagents, and are difficult to detect by conventional analytical methods. TATP and HMTD were securely synthesized, taken up with acetone, hydrolyzed with 4 M HCl to hydrogen peroxide, the acidic solution containing H2O2 was neutralized, and assayed by the copper(II)-neocuproine spectrophotometric method. The chromophore of the reaction was the Cu(I)-neocuproine chelate responsible for light absorption at 454 nm. The molar absorptivity (epsilon) of the method for TATP and HMTD was 3.45 x 10(4) and 4.68 x 10(4) L mol(-1) cm(-1), respectively. The TATP recovery from a synthetically contaminated loamy clay soil was 91-99%. The colorimetric method was also applied to a Cu(II)-neocuproine-impregnated polymeric Nafion membrane sensor developed for the first time in this work for peroxide explosive assay. The absorbance-concentration response was perfectly linear, and the limit of detection (LOD) of the procedure for both TATP and HMTD was approximately 0.2 mg L-1. Neither common soil ions (Ca2+, K+, Cl-, SO42-, Mg2+ and NO3-) at 100-fold amounts nor military-purpose nitro-explosives of TNT, RDX, and PETN at 10-fold amounts interfered with the proposed assay. Active oxygen constituents of laundry detergents (perborates and percarbonates), which normally interfered with the assay, could easily be separated from the analytes by solubility differences. The method was statistically validated against standard reference methods of TiOSO4 colorimetry and GC-MS.
dc.language.isoeng
dc.subjectKimya
dc.subjectKİMYA, ANALİTİK
dc.subjectTemel Bilimler
dc.subjectAnalitik Kimya
dc.subjectTemel Bilimler (SCI)
dc.titleDetermination of peroxide-based explosives with copper(II)-neocuproine assay combined with a molecular spectroscopic sensor
dc.typeMakale
dc.relation.journalANALYST
dc.contributor.departmentİstanbul Üniversitesi , ,
dc.identifier.volume135
dc.identifier.issue8
dc.identifier.startpage2085
dc.identifier.endpage2091
dc.contributor.firstauthorID23496


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster