Basit öğe kaydını göster

dc.contributor.authorSAĞLAM, ŞENER
dc.contributor.authorAPAK, MUSTAFA REŞAT
dc.contributor.authorARDA, AYŞEM
dc.date.accessioned2023-02-21T10:23:25Z
dc.date.available2023-02-21T10:23:25Z
dc.date.issued2022
dc.identifier.citationSAĞLAM Ş., ARDA A., APAK M. R., "Direct Determination of Peroxide Explosives on Polycarbazole/Gold Nanoparticle-Modified Glassy Carbon Sensor Electrodes Imprinted for Molecular Recognition of TATP and HMTD", Analytical Chemistry, cilt.94, sa.50, ss.17662-17669, 2022
dc.identifier.issn0003-2700
dc.identifier.othervv_1032021
dc.identifier.otherav_42d19a00-9218-4671-8e5a-e9bc7fc3001b
dc.identifier.urihttp://hdl.handle.net/20.500.12627/188357
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85143856915&origin=inward
dc.identifier.urihttps://doi.org/10.1021/acs.analchem.2c04450
dc.description.abstract© 2022 American Chemical Society. All rights reserved.Since peroxide-based explosives (PBEs) lack reactive functional groups, they cannot be determined directly by most detection methods and are often detected indirectly by converting them to H2O2. However, H2O2 may originate from many sources, causing false positives in PBE detection. Here, we developed a novel electrochemical sensor for the direct sensitive and selective determination of PBEs such as triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD) using electrochemical modification of the glassy carbon (GC) electrode with PBE-memory polycarbazole (PCz) films decorated with gold nanoparticles (AuNPs) by cyclic voltammetry (CV). The prepared electrodes were named TATP-memory-GC/PCz/AuNPs (used for TATP determination) and HMTD-memory-GC/PCz/AuNPs (used for HMTD detection). The calibration lines of TATP and HMTD were found in the concentration range of 0.1-1.0 mg L-1 using the net current intensities of differential pulse voltammetry (DPV) versus analyte concentrations. The limit of detection (LOD) commonly found was 15 μg L-1 for TATP and HMTD. The sensor electrodes could separately determine intact TATP and HMTD in the presence of nitro-aromatic, nitramine, and nitrate ester energetic materials. The proposed electrochemical sensing method was not interfered by electroactive substances such as paracetamol, caffeine, acetylsalicylic acid, aspartame, d-glucose, and detergent (containing perborate and percarbonate) used as camouflage materials for PBEs. This is the first molecularly imprinted polymeric electrode for PBEs accomplishing such low LODs, and the DPV method was statistically validated in contaminated clay soil samples against the GC-MS method for TATP and a spectrophotometric method for HMTD using t- and F-tests.
dc.language.isoeng
dc.subjectTemel Bilimler
dc.subjectTemel Bilimler (SCI)
dc.subjectKimya
dc.subjectKİMYA, ANALİTİK
dc.subjectAnalitik Kimya
dc.subjectFizik Bilimleri
dc.titleDirect Determination of Peroxide Explosives on Polycarbazole/Gold Nanoparticle-Modified Glassy Carbon Sensor Electrodes Imprinted for Molecular Recognition of TATP and HMTD
dc.typeMakale
dc.relation.journalAnalytical Chemistry
dc.contributor.departmentİstanbul Üniversitesi-Cerrahpaşa , Mühendislik Fakültesi , Kimya Bölümü
dc.identifier.volume94
dc.identifier.issue50
dc.identifier.startpage17662
dc.identifier.endpage17669
dc.contributor.firstauthorID4203054


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster