Show simple item record

dc.contributor.authorGüler, Omer
dc.contributor.authorAKÇAY, Cemil
dc.contributor.authorNasery, Mohammad Manzoor
dc.contributor.authorSAYIN, BARIŞ
dc.contributor.authorUzdil, Oğuz
dc.contributor.authorÇOŞGUN, TURGAY
dc.contributor.authorCeylan, Oguz
dc.date.accessioned2023-05-29T11:35:54Z
dc.date.available2023-05-29T11:35:54Z
dc.identifier.citationÇOŞGUN T., Ceylan O., Nasery M. M., Güler O., SAYIN B., Uzdil O., AKÇAY C., "Seismic performance assessment and retrofitting proposal for a historic masonry school building (Bursa, Türkiye)", Case Studies in Construction Materials, cilt.18, 2023
dc.identifier.issn2214-5095
dc.identifier.othervv_1032021
dc.identifier.otherav_07c44beb-6c71-4621-b094-8067fc2c1e19
dc.identifier.urihttp://hdl.handle.net/20.500.12627/188653
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85153056832&origin=inward
dc.identifier.urihttps://doi.org/10.1016/j.cscm.2023.e02087
dc.description.abstractThe current paper presents all stages of a masonry building restoration including seismic performance assessment of the restored building, and a seismic retrofitting proposal accordingly. All these practices were carried out on a historical school building with timber slabs constructed in 1912. The study was composed of six stages: i. Historical research to identify all previous interventions in the building, ii. On-site examinations to determine the geometrical and structural properties of the building, iii. Laboratory tests to identify original material properties and determine repair materials, iv. Restoration decision and implementation of the restoration, v. Numerical analyses to assess the seismic performance of the restored building, and vi. Retrofitting proposal. The primary aim of this study is to present a comprehensive guide for seismic performance assessment and retrofitting approaches for similar buildings. The story shear forces and inter-story drifts of the examined building were obtained by linear and nonlinear analyses and compared with the limit values given in the applicable seismic code; accordingly, the seismic performance of the building was assessed. On the other hand, vertical and lateral bending collapse mechanisms were determined by local analyses. Based on the obtained findings, the building was found to have sufficient displacement capacity; however, failed in shear. Additionally, we believe that the presented restoration practices and seismic performance assessment aiming the structural integrity of the historic building will contribute to the literature.
dc.language.isoeng
dc.subjectMALZEME BİLİMİ, BİYOMATERYAL
dc.subjectMalzeme Bilimi (çeşitli)
dc.subjectMühendislik ve Teknoloji
dc.subjectMalzeme Bilimi
dc.subjectFizik Bilimleri
dc.subjectMühendislik, Bilişim ve Teknoloji (ENG)
dc.titleSeismic performance assessment and retrofitting proposal for a historic masonry school building (Bursa, Türkiye)
dc.typeMakale
dc.relation.journalCase Studies in Construction Materials
dc.contributor.departmentİstanbul Üniversitesi-Cerrahpaşa , Mühendislik Fakültesi , İnşaat Mühendisliği Bölümü
dc.identifier.volume18
dc.contributor.firstauthorID4265489


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record