Why electrophysiological reassessment is needed? The experience of our laboratory - A cross-sectional study

Tarih
2022
Yazar
Gencdal, Isil
ELMALI YAZICI, Ayşe Deniz
Emekli, Ahmed Serkan
Oege, Ali Emre
ÖZDAĞ ACARLI, Ayşe Nur
BASLO, Mehmet Barış
KOCASOY ORHAN, Elif
Üst veri
Tüm öğe kaydını göster
Özet
Introduction: Requesting repetition of an electrodiagnostic examination (EDX) for follow-up and/or diagnostic verification is common in the daily practice of a reference center. Objective: This study aimed to evaluate demographical and electrophysiological characteristics of the patients who were referred to a reference electrophysiology laboratory for reassessment, to explore the underlying reasons, and motives for ordering a reassessment. Methods: Patients who had at least one EDX study within the last year in one of the two different time periods (winter and summer) were included in the study. Their demographical features, preliminary diagnosis, and electrophysiological findings were assessed and compared with their previous EDX interpretations. Results: Thirty-five (14 female, 21 male) patients (7,7%) out of 457 patients from the winter period (November 11, 2018-December 12, 2018) and 38 (20 female, 18 male) patients (7,8%) out of 487 patients from the summer period (July 01, 2019-August 08, 2019) were included in the study. Age, gender, preliminary diagnosis, and the number of previous electrophysiologic tests were statistically similar between the two groups. The most common reason for reassessment was to verify or to follow-up on a diagnosis of motor neuron disease or polyneuropathy. Compared to the summer group, the patients who had previous EDX in a different center were more common in the winter group, mean duration between EDX studies was also shorter. Conclusion: In this study, we have inspected the patients referred to our laboratory within two different time frames in a year for a repeat EDX study. It was observed that the number of patients who underwent a repeat EDX was relatively low, and there was no significant difference not only in the preliminary diagnosis but also in the electrophysiological findings.
Bağlantı
http://hdl.handle.net/20.500.12627/189934
https://doi.org/10.4103/nsn.nsn_233_21
Koleksiyonlar
  • Makale [92796]

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV
 

 


Hakkımızda
Açık Erişim PolitikasıVeri Giriş Rehberleriİletişim
sherpa/romeo
Dergi Adı/ISSN || Yayıncı

Exact phrase only All keywords Any

BaşlıkbaşlayaniçerenISSN

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTürlere Göre

Hesabım

GirişKayıt

Creative Commons Lisansı

İstanbul Üniversitesi Akademik Arşiv Sistemi (ilgili içerikte aksi belirtilmediği sürece) Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.

DSpace software copyright © 2002-2016  DuraSpace
İletişim | Geri Bildirim
Theme by 
Atmire NV