Show simple item record

dc.contributor.authorKulli, Hilal Denizoglu
dc.contributor.authorArslan, Yunus Ziya
dc.contributor.authorKARABULUT, DERYA
dc.date.accessioned2023-10-10T12:49:32Z
dc.date.available2023-10-10T12:49:32Z
dc.date.issued2023
dc.identifier.citationKulli H. D., KARABULUT D., Arslan Y. Z., "The prolonged effect of Kinesio Taping on joint torque and muscle activity", SOMATOSENSORY AND MOTOR RESEARCH, sa.1, ss.39-45, 2023
dc.identifier.issn0899-0220
dc.identifier.othervv_1032021
dc.identifier.otherav_26cce9ac-13ca-436d-b086-644f15317017
dc.identifier.urihttp://hdl.handle.net/20.500.12627/190280
dc.identifier.urihttps://doi.org/10.1080/08990220.2022.2157394
dc.description.abstractPurposeAlthough Kinesio Taping has been extensively used, evidence about the effect of Kinesio Taping is still insufficient. The aim is to determine the effect of Kinesio Taping on elbow joint torque and muscle activity in time and frequency domains.Materials and MethodsThirty-eight healthy subjects were (27 females and 11 males) randomly divided into control and Kinesio Taping groups. Kinesio Taping was applied over biceps brachii muscle in Kinesio Taping group, whereas no taping was applied to control group. Maximum elbow joint torque and electromyography activity in time and frequency domains were assessed during maximum isometric contraction of biceps brachii muscle at baseline, after 10 min, 30 min, and 24 h. Repeated measure ANOVA and mixed ANOVA tests were used for in-group and between-group comparisons, respectively.ResultsElbow joint torques among four assessment sessions were statistically altered in Kinesio Taping group and greater in Kinesio Taping group than in control group (F(3,57)= 3.317, p = 0.026, eta p2 = 0.149; F(3,108)=3.325, p = 0.022, eta p2 = 0.085; respectively). No difference was found in time domain muscle activity among assessment sessions in each group and comparison of groups (p > 0.05). Low-gamma band activity was changed among assessment sessions in Kinesio Taping group (F(3,57)= 6.946, p < 0.001, eta p2 = 0.268) while group x time interaction was not determined.ConclusionsKinesio Taping may influence joint torque of elbow more than without Kinesio Taping condition in 24th hour but the interpretation of this effect as a muscle strength enhancement compared with baseline can be arguable. Even if Kinesio Taping could not affect muscle activity in time domain, low-gamma band activity which is closely related to somatosensorial input may reach highest magnitude 24 h after Kinesio Taping.
dc.language.isoeng
dc.subjectTemel Bilimler
dc.subjectDuyusal Sistemler
dc.subjectGelişimsel Sinirbilim
dc.subjectBilişsel Sinirbilim
dc.subjectHücresel ve Moleküler Sinirbilim
dc.subjectSinirbilim (çeşitli)
dc.subjectGenel Sinirbilim
dc.subjectİnsan Bilgisayar Etkileşimi
dc.subjectFizik Bilimleri
dc.subjectYaşam Bilimleri (LIFE)
dc.subjectSinirbilim ve Davranış
dc.subjectSİNİR BİLİMİ
dc.subjectYaşam Bilimleri
dc.titleThe prolonged effect of Kinesio Taping on joint torque and muscle activity
dc.typeMakale
dc.relation.journalSOMATOSENSORY AND MOTOR RESEARCH
dc.contributor.departmentİstanbul Atlas Üniversitesi , ,
dc.identifier.issue1
dc.identifier.startpage39
dc.identifier.endpage45
dc.contributor.firstauthorID4311509