Basit öğe kaydını göster

dc.contributor.authorErgin, Omer Naci
dc.contributor.authorSadic, Betul
dc.contributor.authorAsik, Mehmet
dc.contributor.authorYavuz, Serap Simsek
dc.contributor.authorKocazeybek, Emre
dc.contributor.authorDemirel, Mehmet Cüneyd
dc.contributor.authorErsin, Mehmet
dc.date.accessioned2021-03-02T16:06:06Z
dc.date.available2021-03-02T16:06:06Z
dc.date.issued2020
dc.identifier.citationKocazeybek E., Demirel M. C. , Ersin M., Ergin O. N. , Sadic B., Yavuz S. S. , Asik M., "Abiotrophia defectiva as a Rare Causative Agent of Periprosthetic Total Knee Arthroplasty Infections: A Case Report and Literature Review", JOURNAL OF LABORATORY PHYSICIANS, cilt.12, ss.219-221, 2020
dc.identifier.otherav_f11edf26-344a-43f7-8758-db5f2bb91b1b
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/2300
dc.identifier.urihttps://doi.org/10.1055/s-0040-1720942
dc.description.abstractWe present a case of Abiotrophia defectiva in a prosthetic knee infection following total knee replacement for the first time. A 69-year-old female was prediagnosed with prosthetic knee infection, and a two-stage revision arthroplasty was applied. A. defectiva was cultured by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) from the synovial fluid aspirates. Penicillin G and gentamicin had been administered. One year postoperatively, a scintigraphy showed no recurrence. A. defectiva may be missed in culture negative patients with knee or hip arthroplasty. They should be carefully evaluated if they have undergone recent dental procedures.
dc.language.isoeng
dc.subjectHealth Sciences
dc.subjectTIP, GENEL & İÇECEK
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (MED)
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectTemel Tıp Bilimleri
dc.subjectFamily Practice
dc.subjectFundamentals and Skills
dc.subjectGeneral Health Professions
dc.subjectPathophysiology
dc.subjectInternal Medicine
dc.subjectAssessment and Diagnosis
dc.subjectMedicine (miscellaneous)
dc.subjectGeneral Medicine
dc.titleAbiotrophia defectiva as a Rare Causative Agent of Periprosthetic Total Knee Arthroplasty Infections: A Case Report and Literature Review
dc.typeMakale
dc.relation.journalJOURNAL OF LABORATORY PHYSICIANS
dc.contributor.departmentİstanbul Üniversitesi , İstanbul Tıp Fakültesi , Cerrahi Tıp Bilimleri Bölümü
dc.identifier.volume12
dc.identifier.issue3
dc.identifier.startpage219
dc.identifier.endpage221
dc.contributor.firstauthorID2371041


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster