Basit öğe kaydını göster

dc.contributor.authorKiral, A
dc.contributor.authorSolakoglu, C
dc.contributor.authorMahirogullari, M
dc.contributor.authorAkmaz, I
dc.contributor.authorPehlivan, O
dc.contributor.authorKuskucu, M
dc.contributor.authorRodop, O
dc.date.accessioned2021-03-03T09:00:03Z
dc.date.available2021-03-03T09:00:03Z
dc.date.issued2004
dc.identifier.citationAkmaz I., Kiral A., Pehlivan O., Mahirogullari M., Solakoglu C., Rodop O., Kuskucu M., "Late reconstruction of neglected metacarpal shaft defects due to gunshot wound", JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, sa.6, ss.585-589, 2004
dc.identifier.issn0266-7681
dc.identifier.othervv_1032021
dc.identifier.otherav_1aa6bf93-35af-40a5-9369-62893df5a344
dc.identifier.urihttp://hdl.handle.net/20.500.12627/23205
dc.identifier.urihttps://doi.org/10.1016/j.jhsb.2004.05.009
dc.description.abstractWe evaluated eight patients after delayed treatment of nine metacarpal bone defects due to gunshot injuries. The mean length of the metacarpal defects was 3 cm and the average time between the gunshot injury and the reconstruction surgery was 10 months. Although all of the patients had been treated with wound irrigation and debridement immediately following injury, no attempt had been made to repair the metacarpal defect or to maintain metacarpal length. As a result, serious shortening had occurred. After the original length of the metacarpal had been restored by distraction of the soft tissues (1 mm/day), a tri-cortical iliac bone graft was inserted into the bone defect. The average follow-up time was 15 months. Clinical and radiological union was established in all cases after an average of 12 weeks. The mean grip strength of the hand and the mean range of motion of the metacarpophalangeal joint increased by 24% and 60%, respectively.
dc.language.isoeng
dc.subjectCerrahi Tıp Bilimleri
dc.subjectOrtopedi ve Travmatoloji
dc.subjectORTOPEDİ
dc.subjectKlinik Tıp
dc.subjectKlinik Tıp (MED)
dc.subjectCERRAHİ
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.titleLate reconstruction of neglected metacarpal shaft defects due to gunshot wound
dc.typeMakale
dc.relation.journalJOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME
dc.contributor.department, ,
dc.identifier.issue6
dc.identifier.startpage585
dc.identifier.endpage589
dc.contributor.firstauthorID173412


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster