Basit öğe kaydını göster

dc.contributor.authorALTIOK, E
dc.contributor.authorURGANCIOGLU, I
dc.contributor.authorSONMEZOGLU, K
dc.contributor.authorISITMAN, AT
dc.contributor.authorKAPICIOGLU, T
dc.contributor.authorKABASAKAL, L
dc.contributor.authorTUROGLU, HT
dc.contributor.authorONSEL, C
dc.contributor.authorOZKER, K
dc.contributor.authorUSLU, I
dc.contributor.authorATAY, S
dc.contributor.authorCANSIZ, T
dc.date.accessioned2021-03-03T09:18:47Z
dc.date.available2021-03-03T09:18:47Z
dc.date.issued1995
dc.identifier.citationKABASAKAL L., TUROGLU H., ONSEL C., OZKER K., USLU I., ATAY S., CANSIZ T., SONMEZOGLU K., ALTIOK E., ISITMAN A., et al., "CLINICAL COMPARISON OF TECHNETIUM-99M-EC, TECHNETIUM-99M-MAG3 AND IODINE-131-OIH IN RENAL DISORDERS", JOURNAL OF NUCLEAR MEDICINE, cilt.36, sa.2, ss.224-228, 1995
dc.identifier.issn0161-5505
dc.identifier.othervv_1032021
dc.identifier.otherav_1c5427a9-449d-4aba-a77e-50525159013f
dc.identifier.urihttp://hdl.handle.net/20.500.12627/24289
dc.description.abstractTechnetium-99m-ethylenedicysteine has recently been developed for renal function studies. The pharmacokinetics of Tc-99m-EC were studied by constant infusion technique and compared with Tc-99m-MAG3 and I-131-OIH in, 11 patients with various renal disorders. Methods: After giving a 7.4 MBq I-131-OIH and 90-110 MBq Tc-99m-EC or Tc-99m-MAG3 bolus, a constant infusion (1 MBq/ml Tc-99m-agent and 0.07 MBq/m I-131-OIH was started. Sixteen blood and five urine samples were obtained over three hr. Results: The renal clearance of Tc-99m-EC was higher than that of Tc-99m-MAG3. The Tc-99m-EC/OIH and (99m)TcMAG3/OIH ratios were 0.75 +/- 0.05 and 0.55 +/- 0.10 (p = 0.00087), respectively. The distribution volume of Tc-99m-EC was also higher than that of Tc-99m-MAG3 (15722 +/- 4644 and 9509 +/- 2788 m1/1.73m(2), respectively; p = 0.072). The Tc-99m-EC/OIH and Tc-99m-MAG3/OIH distribution volume ratios were 1.03 +/- 0.14 and 0.55 +/- 0.10, respectively (p = 0.0003). The 60-min excretion values of Tc-99m-EC and Tc-99m-MAG3 were compared to that of OIH. The Tc-99m-EC/OIH and Tc-99m-MAG3/OIH excretion ratios were 0.96 +/- 0.06 and 1.07 +/- 0.10, respectively (p = 0.162). The protein binding of Tc-99m-EC and OIH were found to be 34% +/- 4 and 66% +/- 5, respectively (p < 0.0001). The red cell binding of Tc-99m-EC was negligible (3% +/- 1.2) in comparison to OIH (27% +/- 3; p < 0.0001). Conclusion: This limited study demonstrates the pharmacokinetic and renal clearance properties of Tc-99m-EC. This agent has good potential for renal function evaluation.
dc.language.isoeng
dc.subjectTıp
dc.subjectNükleer Tıp
dc.subjectSağlık Bilimleri
dc.subjectDahili Tıp Bilimleri
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectRADYOLOJİ, NÜKLEER TIP ve MEDİKAL GÖRÜNTÜLEME
dc.titleCLINICAL COMPARISON OF TECHNETIUM-99M-EC, TECHNETIUM-99M-MAG3 AND IODINE-131-OIH IN RENAL DISORDERS
dc.typeMakale
dc.relation.journalJOURNAL OF NUCLEAR MEDICINE
dc.contributor.department, ,
dc.identifier.volume36
dc.identifier.issue2
dc.identifier.startpage224
dc.identifier.endpage228
dc.contributor.firstauthorID116017


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster