dc.contributor.author | Korkmaz, Yonca | |
dc.contributor.author | Firatli, Erhan | |
dc.contributor.author | Ozel, Emre | |
dc.contributor.author | Bicer, Ceren Ozge | |
dc.contributor.author | ATTAR, NURAY | |
dc.date.accessioned | 2021-03-03T10:39:50Z | |
dc.date.available | 2021-03-03T10:39:50Z | |
dc.date.issued | 2008 | |
dc.identifier.citation | ATTAR N., Korkmaz Y., Ozel E., Bicer C. O. , Firatli E., "Microleakage of Class V Cavities with Different Adhesive Systems Prepared by a Diamond Instrument and Different Parameters of Er:YAG Laser Irradiation", PHOTOMEDICINE AND LASER SURGERY, cilt.26, sa.6, ss.585-591, 2008 | |
dc.identifier.issn | 1549-5418 | |
dc.identifier.other | av_23eebdae-d3ee-4dc8-b47c-22c051078712 | |
dc.identifier.other | vv_1032021 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12627/29076 | |
dc.identifier.uri | https://doi.org/10.1089/pho.2007.2203 | |
dc.description.abstract | Objective: The aim of this study was to evaluate the microleakage of composite resin restorations using two different dentine adhesive systems prepared with a diamond instrument and different parameters of Er:YAG laser irradiation. Background Data: Information on this topic with regard to preparing class V cavities with different parameters of Er: YAG laser irradiation and adhesive systems is scarce. Materials and Methods: Two hundred class V cavities were assigned to ten groups (n = 20 each): group 1: Er: YAG laser (5 Hz, 600 mJ) + phosphoric acid (PA) + Adper Single Bond 2 (ASB2); group 2: Er: YAG laser (10 Hz, 300 mJ) + PA + ASB2; group 3: Er: YAG laser (15 Hz, 200 mJ) + PA + ASB2; group 4: Er: YAG laser (20 Hz, 150 mJ) + PA + ASB2; group 5: diamond instrument + PA + ASB2; group 6: Er: YAG laser (5 Hz, 600 mJ) + Adper Prompt L-Pop (APLP); group 7: Er: YAG laser (10 Hz, 300 mJ) + APLP; group 8: Er: YAG laser (15 Hz, 200 mJ) + APLP; group 9: Er: YAG laser (20 Hz, 150 mJ) + APLP; and group 10: diamond instrument + APLP. Cavities were restored with a nanofill composite (Filtek Supreme XT Body). After thermocycling, the specimens were stained with 0.5% aqueous basic fuchsin dye and sectioned bucco-lingually. Dye penetration was then scored. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests with Bonferroni correction. The Wilcoxon signed ranks test was used to compare occlusal and gingival scores. Results: Leakage was seen in all groups at both the occlusal and gingival margins. The Kruskal-Wallis test showed statistically significant differences among the 10 groups (p 5), 5 and 7 (7 > 5), and 7 and 8 (7 > 8) at the gingival margin, and between groups 3 and 6 (6 > 3), 3 and 7 (7 > 3), 4 and 6 (6 > 4), and 4 and 7 (7 > 4) at the occlusal margin. Conclusion: We concluded that for all groups, microleakage values were higher at the gingival margins. The use of the Er: YAG laser for cavity preparation with different parameters and different dentine adhesive systems influenced the marginal sealing of composite resin restorations. | |
dc.language.iso | eng | |
dc.subject | Klinik Tıp (MED) | |
dc.subject | Sağlık Bilimleri | |
dc.subject | CERRAHİ | |
dc.subject | Klinik Tıp | |
dc.subject | Tıp | |
dc.subject | Cerrahi Tıp Bilimleri | |
dc.title | Microleakage of Class V Cavities with Different Adhesive Systems Prepared by a Diamond Instrument and Different Parameters of Er:YAG Laser Irradiation | |
dc.type | Makale | |
dc.relation.journal | PHOTOMEDICINE AND LASER SURGERY | |
dc.contributor.department | Hacettepe Üniversitesi , Diş Hekimliği Fakültesi , Restoratif Diş Tedavisi A.B.D. | |
dc.identifier.volume | 26 | |
dc.identifier.issue | 6 | |
dc.identifier.startpage | 585 | |
dc.identifier.endpage | 591 | |
dc.contributor.firstauthorID | 190254 | |