Extraction of a foreign body from the breast parenchyma using radioguided occult lesion localisation (ROLL) technique: a new approach
Date
2010Author
Aydogan, F.
ATASOY, Deniz
Gazioğlu, Emrullah
Dikici, A. Sueleyman
Olgun, DENİZ
Aliyev, A.
Metadata
Show full item recordAbstract
The radioguided occult lesion localisation (ROLL) technique is used for the excision of non-palpable breast lesions. This technique has not been described previously for the extraction of foreign bodies from the breast parenchyma. We report here a female patient who was admitted to our hospital with a foreign body in her right breast. The ROLL technique was used for the extraction of the foreign body.