dc.identifier.citationBilhan H., Cilingir A., Bural C., Bilmenoglu C., Sakar O., Geckili O., "The Evaluation of the Reliability of Periotest for Implant Stability Measurements: An In Vitro Study", JOURNAL OF ORAL IMPLANTOLOGY, cilt.41, sa.4, 2015
dc.identifier.issn0160-6972
dc.identifier.otherav_3caf3071-f2c3-41dc-bafa-728ff4df5964
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/44711
dc.identifier.urihttps://doi.org/10.1563/aaid-joi-d-13-00303
dc.description.abstractPeriotest (Medizintechnik Gulden, Modautal, Germany) is a widely accepted implant stability measurement method, although the reliability is not well known. The aim of this in vitro study was to investigate the reliability of the Periotest in implant stability measurements. Thirty implants were placed in 3 cow ribs. The stability of each implant was measured by insertion torque, resonance frequency analyses, and Periotest and then compared. The Periotest values (PTVs) were measured by 4 different examiners. The measurements were repeated twice in both the buccal and mesial directions, for each implant at 2-hour intervals and the intra-and interobserver reliability of Periotest was measured. Results showed that the intraobserver reliability of the Periotest was excellent for the buccal PTVs but fair to poor for the mesial PTVs. The interobserver reliability of the Periotest was excellent for the buccal PTVs but poor for the mesial PTVs. No significance was found between the PTVs and IT values (P =.803) and PTVs and ISQ values, whereas a 47.1% significant correlation was detected between the IT values and ISQ values (P =.009). The present study indicates that only Periotest measurements from buccal result in excellent intra-and interobserver reliability for the quantification of the implant stability.
dc.language.isoeng
dc.subjectKlinik Tıp
dc.subjectDiş Hekimliği
dc.subjectSağlık Bilimleri
dc.subjectTıp
dc.subjectKlinik Tıp (MED)
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.titleThe Evaluation of the Reliability of Periotest for Implant Stability Measurements: An In Vitro Study
dc.typeMakale
dc.relation.journalJOURNAL OF ORAL IMPLANTOLOGY
dc.contributor.departmentİstanbul Okan Üniversitesi , ,
dc.identifier.volume41
dc.identifier.issue4
dc.contributor.firstauthorID73176


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster