Basit öğe kaydını göster

dc.contributor.authorTutem, Esma
dc.contributor.authorBaskan, Kevser
dc.contributor.authorAkyuz, Esin
dc.contributor.authorAPAK, Resat
dc.date.accessioned2021-03-02T18:09:53Z
dc.date.available2021-03-02T18:09:53Z
dc.date.issued2020
dc.identifier.citationAkyuz E., Baskan K., Tutem E., APAK R., "Novel Iron(III)-Induced Prooxidant Activity Measurement Using a Solid Protein Sensor in Comparison with a Copper(II)-Induced Assay", ANALYTICAL LETTERS, cilt.53, ss.1489-1503, 2020
dc.identifier.issn0003-2719
dc.identifier.otherav_c4791b78-e415-4d34-a943-5c9ab2044de7
dc.identifier.othervv_1032021
dc.identifier.urihttp://hdl.handle.net/20.500.12627/4628
dc.identifier.urihttps://doi.org/10.1080/00032719.2019.1710180
dc.description.abstractThe iron(III) and Cu(II) reducing ability of common antioxidants may be an indirect measure of their prooxidant activity, because the reduced ions may generate reactive oxygen species (ROS). This study aimed to develop a new Fe(III)-ferrozine spectrophotometric prooxidant activity assay using a protein - based solid biosensor prepared from Ca(II) and chicken egg whites. This new assay involved the reduction of Fe(III) ions to Fe(II) by antioxidant compounds and the binding of the formed Fe(II) to the solid biosensor. As an indicator of the prooxidant activity of antioxidants on proteins, the protein - bound Fe(II) was colorimetrically determined with ferrozine at 562 nm. The prooxidant activities of antioxidant compounds such as gallic acid, catechin, epicatechin, epigallocatechin gallate, and chlorogenic acid were determined across a wide range of final concentrations between 0.25 and 2500 mu M. Most of the tested compounds showed prooxidant activity above a concentration of 2.50 mu M with the Fe(III)-based method. In addition, the findings of the new method were compared with those of the modified Cu(II)-neocuproine (Nc) method previously developed by the same authors based on the principle of copper(II) reduction by antioxidants in the presence of a Ca(II)-proteinate sensor.
dc.language.isoeng
dc.subjectAnalytical Chemistry
dc.subjectFiltration and Separation
dc.subjectChemistry (miscellaneous)
dc.subjectGeneral Chemistry
dc.subjectPhysical Sciences
dc.subjectAnalitik Kimya
dc.subjectTemel Bilimler
dc.subjectTemel Bilimler (SCI)
dc.subjectKimya
dc.subjectKİMYA, ANALİTİK
dc.titleNovel Iron(III)-Induced Prooxidant Activity Measurement Using a Solid Protein Sensor in Comparison with a Copper(II)-Induced Assay
dc.typeMakale
dc.relation.journalANALYTICAL LETTERS
dc.contributor.departmentİstanbul Üniversitesi , Mühendislik , Kimya
dc.identifier.volume53
dc.identifier.issue9
dc.identifier.startpage1489
dc.identifier.endpage1503
dc.contributor.firstauthorID66073


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster