Show simple item record

dc.contributor.authorDestanoglu, Orhan
dc.contributor.authorCansever, Mehmet Serif
dc.contributor.authorYılmaz, Gülçin
dc.date.accessioned2021-03-03T16:40:21Z
dc.date.available2021-03-03T16:40:21Z
dc.date.issued2015
dc.identifier.citationDestanoglu O., Cansever M. S. , Yılmaz G., "Determination of Ethylmalonic Acid in Human Urine by Ion Chromatography with Suppressed Conductivity", ORBITAL-THE ELECTRONIC JOURNAL OF CHEMISTRY, cilt.7, sa.2, ss.131-140, 2015
dc.identifier.othervv_1032021
dc.identifier.otherav_457fc31f-db7e-43f9-bfb1-ce0c1acb6e2d
dc.identifier.urihttp://hdl.handle.net/20.500.12627/50385
dc.description.abstractWe present here a new method for the determination of EMA in urine by ion chromatography (IC) with suppressed conductivity detection. The separations on an anion exchange column have been accomplished with an optimized multi-step gradient eluent program (5 mM for 0-7 min, 5-50 mM from 7 to 30 min, 50 mM for 30-40 min, 50-5 mM from 40 to 45 min, 5mM for 45-50 min at flow-rate 0.2 mL/min) using NaOH as the eluent. The temperatures of both the column and suppressed conductivity detector were 40 degrees C. The suppressor current was 25 mA. The injection loop volume was 100 mu L. Prior to injection, a clean-up procedure has been applied to urine samples for sulfate removal using BaCl2 precipitation followed by elimination of cationic and some organic compounds using strongly acid cation-exchange resin and C18 solid phase extraction cartridge, respectively. Concentration range of EMA for linear external calibration curve was between 0.202 -30.278 mu mol/L (r(2)=0.999). The limit of detection and the limit of quantitation were 61 nmol/L and 202 nmol/L based on the signal-to-noise ratio equal to 3 and 10, respectively. The average recoveries of EMA for normal urine samples were between 98.2-99.3 % with less than 1.1 % relative standard deviation (RSD), and for pathological sample were between 97.2-107.8% with less than 1.9% RSD in both intra-day and inter-day assays. The average concentrations of EMA normalized against creatinine for healthy human urine samples and a pathological sample were 1.14 (0.88-1.50) and 128.95 (128.04-129.33) mu mol mmol-1 creatinine, respectively.
dc.language.isoeng
dc.subjectTemel Bilimler
dc.subjectBiyokimya
dc.subjectAlkoloidler
dc.subjectTemel Bilimler (SCI)
dc.subjectKimya
dc.subjectKİMYA, MULTİDİSİPLİNER
dc.titleDetermination of Ethylmalonic Acid in Human Urine by Ion Chromatography with Suppressed Conductivity
dc.typeMakale
dc.relation.journalORBITAL-THE ELECTRONIC JOURNAL OF CHEMISTRY
dc.contributor.departmentİstanbul Teknik Üniversitesi , ,
dc.identifier.volume7
dc.identifier.issue2
dc.identifier.startpage131
dc.identifier.endpage140
dc.contributor.firstauthorID221609


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record